Справочник Пользователя для Intel SERVER CHASSIS SR2500 SR2500

Модели
SR2500
Скачать
Страница из 115
Product Overview 
Intel® Server System SR2500AL 
 
 
Revision – 1.00 
Intel order number D31980-004 
 
 
1.7 Power 
Sub-system 
The power subsystem of the chassis consists of an integrated power distribution board and 
module enclosure which is capable of housing up to two 750 Watt power supply modules 
supporting 1+0 or redundant 1+1 power configurations. In a 1+1 redundant configuration, each 
power supply module is hot-swappable should one fail.  
The power sub-system has several integrated management features including: 
•  Status LED on each power module 
•  Over-temperature protection circuitry 
•  Over-voltage protection circuitry 
With the addition of server management software, the power subsystem is capable of 
supporting several system management features including: 
•  Remote Power On/Off 
• Status 
Alerting 
•  FRU Information Reporting 
Each power supply module operates within the following voltage ranges and ratings: 
PARAMETER 
MIN 
RATED 
MAX 
Start-up 
Vac 
Power 
Off 
Vac 
Max Input 
AC Current 
Max Rated 
Input AC 
Current 
Line Voltage 
(110) 
90V
rms
 100-127 
V
rms
 140V
rms
 
85Vac 
±4Vac 
75Vac 
±5Vac 
12 A
rms
1,3
 11.0A
rms
 
Line Voltage 
(220) 
180V
rms
 200-240 
V
rms
 264V
rms
 - 
6.0 
A
rms
2,3 
5.5A
rms
 
Frequency 
47 Hz 
50/60Hz 
63 Hz 
 
 
 
 
Maximum input current at low input voltage range shall be measured at 90Vac, at max load. 
Maximum input current at high input voltage range shall be measured at 180VAC, at max load.   
This is not to be used for determining agency input current markings.
 
Maximum rated input current is measured at 100VAC and 200VAC.
 
1.8 System 
Cooling 
The chassis is offered with two system cooling options. The first option is a three fan solution 
providing sufficient airflow to maintain internal system thermal requirements when the external 
ambient temperature remains within specified limits. The second option is a 5+1 fan 
configuration. Refer to section 3.2 for details.  Should a single fan failure occur, this option 
provides support for hot-swap fans and fan redundancy. 
In addition to the system fan options, each power supply module installed provides two 
additional non-redundant fans which pull air from inside the chassis out the back. 
1.9 Chassis 
Security 
The chassis provides support for a lockable front bezel which prevents unauthorized access to 
the system control buttons and hard drives.  In addition, a chassis intrusion switch is provided 
allowing server management software to monitor removal of the top cover from the chassis.