Intel® Server System SR2500AL Cooling 
Subsystem 
Revision – 1.00 
 
 
Intel order number D31980-004 
21
3.1  Non-redundant Fan Module 
TP02119
 
Figure 15. Non-Redundant Fan Module 
This option provides the primary airflow for system configurations that do not require redundant 
cooling. 
Table 13  Nonredundant Cooling Zones 
 
 
 
 
 
 
The system fan module has been designed for ease of use and has support for several 
management features that can be utilized by the server board management system.   
•  The fan module houses two different fan sizes.  System fans 1 and 2 use an 80mm fan, 
while system fan 3 uses a 60mm fan. 
•  Each fan is designed for tool-less insertion to or removal from the fan module housing.  
Note:  The fans are NOT hot-swappable. The system must be turned off in order to 
replace a failed fan. 
•  Each fan within the module is capable of supporting multiple speeds. If the internal 
ambient temperature of the system exceeds the value programmed into the thermal 
sensor data record (SDR), the BMC firmware will increase the speed for all the fans 
within the fan module. 
•  Each fan connector within the module supplies a tachometer signal that allows the BMC 
to monitor the status of each fan. If one of the fans should fail, the remaining fans will 
increase their rotation and attempt to maintain the thermal requirements of the system. 
Fan 
Cooling 
Zone 
Description of greatest cooling influence 
System Fan #1 
CPU1 
Primary cooling for CPU1 and memory 
System Fan #2 
CPU2 
Primary cooling for hard drives 4 and 5, CPU2, 
the MCH, and the low profile PCI cards 
System Fan #3 
PCI 
Primary cooling for hard drives 2 and 3, Full 
Height PCI cards, PXH and IOP80333 chipset 
Power Supply 
Fans 2 fans per 
module 
Power 
Supply 
Primary cooling for  hard drives 0 and 1, and the 
power supply module(s)