  After making the calculations as shown 
above, you should fi nd a compressor 
providing 4.9 CFM of air that is required.
Lubrication
It is important that the Nailer be properly 
lubricated.
Without proper lubrication, the Nailer will not 
work properly and parts will wear prematurely.
 
○ Use Hitachi pneumatic tool lubricant.
 
Do not use detergent oil or additives. These 
lubricants will harm the O-rings and other 
rubber parts. This will cause the Nailer to 
malfunction.
 
○ Filter-regulator-lubricator units should 
always be used.
  Keep the lubricator fi lled with Hitachi 
pneumatic tool lubricant.
 
○ If a lubricator is not available, supply 5 – 10 
drops of Hitachi pneumatic tool lubricant 
into the air plug on the Nailer twice a day.
Cold weather care
 
○ Do not store the Nailer in a cold weather 
environment.  Keep the Nailer in a warm 
area until beginning the work.
 
○ If the Nailer is already cold, bring it in a 
warm area and allow the Nailer to warm up 
before use.
1
  Reduce the air pressure to 64 psi (4.4 
bar   4.5 kgf/cm
2
).
2
  Remove all nails from the Nailer.
3
 Connect the air hose and free-fi re 
(blank-fi re) the Nailer.
 
The lowered air pressure will be enough 
to free-fi re the Nailer.
 
Slow speed operation tends to warm up 
the moving part.
 CAUTION
 
● Do not free-fi re the Nailer at high 
pressure.
Testing the nailer
DANGER 
 
●  Operators and 
others in work 
area MUST wear 
safety glasses 
with side shields 
which conforms 
to ANSI Z87.1 
specifi cations.
WARNING 
 
● Never use Nailer unless push lever 
is operating properly.
Before actually beginning the nailing work, 
test the Nailer by using the check list below. 
Conduct the tests in the following order.
If abnormal operation occurs, stop using the 
Nailer and contact a Hitachi authorized service 
center immediately.
(1) Disconnect air hose from nailer.
 
Remove all nails from nailer.
□  All crews must be tightened.
 
If any screws are loose, tighten them.
□  The push lever and trigger must move 
smoothly.
Trigger
Push 
Lever
Do not connect 
air hose
000Book_NT65MA4(S)_US.indb   10