It is possible to tie the extension cord and power cord in a 
knot to prevent them from becoming disconnected during 
use. Make the knot as shown in figure 1, then connect the 
plug end of the power cord into the receptacle end of the 
extension cord. This method can also be used to tie two 
extension cords together.
**Ampere rating (on product data plate)
 
 
0-2.0 
2.1-3.4 
3.5-5.0  5.1-7.0  7.1-12.0   12.1-16.0
Cord Length   
 Wire Size (A.W.G.)
 
25´ 16  16 16 16 14  14
 
50´ 16  16 16 14 14  12
 
100´ 16  16 14 12 10  —
**Used on 12 gauge - 20 amp circuit
NOTE: AWG = American Wire Gauge
WARNING:
Keep the extension cord clear of the working area. 
Position the cord so that it will not get caught on  
lumber, tools, or other obstructions while you are working 
with a power tool. Failure to do so can result in serious 
personal injury.
WARNING:
Check extension cords before each use. If damaged 
replace immediately. Never use product with a damaged 
cord since touching the damaged area could cause 
electrical shock resulting in serious injury.
DOUBLE INSULATION
Double insulation is a concept in safety in electric power 
tools, which eliminates the need for the usual three-
wire grounded power cord. All exposed metal parts are  
isolated from the internal metal motor components with 
protecting insulation. Double insulated tools do not need 
to be grounded.
WARNING:
The double insulated system is  intended to protect 
the user from shock resulting from a break in the tool’s 
internal insulation. Observe all normal safety precautions 
to avoid electrical shock.
NOTE: Servicing of a product with double insulation requires 
extreme care and knowledge of the system and should 
be performed only by a qualified service technician. For 
service, we suggest you return the tool to your nearest 
authorized service center for repair. Always use original 
factory replacement parts when servicing.
ELECTRICAL CONNECTION
This product has a precision-built electric motor. It should 
be connected to a 
power supply that is 120 volts, AC only 
(normal household current), 60 Hz. Do not operate this 
product on direct current (DC). A substantial voltage drop 
will cause a loss of power and the motor will overheat. If 
your product does not operate when plugged into an outlet, 
double-check the power supply.
GFCI
Ground Fault Circuit Interrupter (GFCI) protection should 
be provided on the circuit(s) or outlet(s) to be used for the 
product. Receptacles are available having built-in GFCI 
protection and may be used for this measure of safety.
EXTENSION CORDS
See Figure 1.
When using a power product at a considerable distance from 
a power source, be sure to use an extension cord that has 
the capacity to handle the current the product will draw. An  
undersized cord will cause a drop in line voltage, resulting in 
overheating and loss of power. Use the chart to determine 
the minimum wire size required in an extension cord. Only 
round jacketed cords listed by Underwriter’s Laboratories 
(UL) should be used.
When working outdoors with a product, use an extension 
cord that is designed for outside use. This type of cord is 
designated with “W-A” or “W” on the cord’s jacket.
Before using any extension cord, inspect it for loose or 
exposed wires and cut or worn insulation.
A proper extension cord is available at an authorized service 
center.