GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS 
VULCAN-HART                                                                                                                F-32934 Rev. J (August 2012) 
-13-
 
 
Solid State Knob Control
 
 
Indicator Lights  
(On/Start/Heating)
 
 
  
Temperature 
Knob 
Control 
      Melt 
Switch 
 
 
 
  Power 
Switch 
       
 
 
Filter 
Switch 
   
 
 
 
 
 
 
 
 
 
      
(For those models with KleenScreen 
 
 
 
 
 
 
 
 
 
 
 
PLUS® Filter Systems) 
 
 
   
Start Button 
 
 
 
 
 
 
 
 
 
 
 
TURNING ON THE FRYER 
 
 
Open the door to the fryer.  Select Liquid or Solid Shortening pressing the switch to 
the desired selection.  
 
 
Set temperature by turning the knob to the desired temperature.  
 
 
Press the power switch to the ON position.  The burners will not light until the next 
step is completed.   
 
 
Press the START switch once for the burners to light.  The START switch is a 
momentary switch and will reset after being pressed.  The indicator light will change 
from Red to Green.  Heating light will glow Yellow. 
 
 
The burners will cycle on and off throughout the melt cycle. When the fry tank oil 
reaches 135° F (57.2 °C) the burners will stop cycling and remain on until the set 
temperature  is reached.  Once set temperature is reached the burners will cycle on 
and off to  
maintaining the set  temperature. 
 
 
TURNING OFF THE FRYER 
 
 
Open the door to the fryer.  Press the power switch to the OFF position.