Справочник Пользователя для Hoshizaki C-100BAF-ADDS

Скачать
Страница из 44
23
3. Other
Problem
Possible Cause
Remedy
[1] Abnormal noise.
a)Fan Motor
1. Bearing worn out.
1. Replace fan motor.
2. Fan blade deformed.
2. Replace fan blade.
3. Fan blade does not 
move freely.
3. Replace fan blade and/or 
fan motor.
b)Compressor 
1. Mounting pad out of 
position.
1. Reinstall.
2. Bearings worn out or 
cylinder valve broken.
2. Replace compressor.
c) Refrigerant Lines
1. Rub or touch lines or 
other surfaces.
1. Reposition.
d)Auger
1. Bearings or auger 
worn out.
1. Replace bearings or 
auger. See "V.C.1. Upper 
Bearing Wear Check."
e)Gear Motor 
1. Bearing or gear worn 
out/damaged.
1. Replace.
f) Evaporator
1. Scale on inside wall 
of evaporator freezing 
cylinder.
1. Use Hoshizaki "Scale 
Away" solution to clean 
periodically. See "VI. A. 
Cleaning and Sanitizing 
Instructions." If the water 
is found hard by testing, 
install a softener.
2. Low refrigerant 
pressures.
2. Check for leaks with a 
leak detector. Check 
charge. Recover, repair, 
replace drier, evacuate, 
and recharge. See "V.A. 
Service for Refrigerant 
Lines."
[2] Overflow from 
reservoir (water does 
not stop).
a)Water Supply
1. Water pressure too 
high.
1. Install a pressure reducing 
valve.
b)Water Valve
1. Does not close.
1. Clean or replace.
c) Float
1. Bad.
1. Check for proper  
operation and replace.
[3] Gear motor protector 
(external overload) 
trips frequently.
a)Power Supply
1. Not within 
specifications.
1. Refer to nameplate and 
correct.
b)Gear Motor Protector
1. Defective.
1. Check and replace.
c) Auger
1. Bearings or auger 
worn out.
1. Replace bearings or 
auger. See "V.C.1. Upper 
Bearing Wear Check."
d)Gear Motor 
1. Bearing or gear worn 
out or damaged.
1. Replace gear motor.
e)Bin Control Thermostat 
Assembly (with 
integrated heater)
1. Bad contacts.
1. Check for continuity 
and replace. See 
"V.F. Removal and 
Replacement of Bin 
Control Thermostat 
Assembly."