D. Optional Drain Pump HS-0248
1. Overview
As ice melts, water drains from the storage bin into the drain pump reservoir. When 
the drain pump's lower float switch closes, the pump motor energizes and pumps out 
the water. If water cannot be pumped out of the drain pump reservoir due to a blocked 
discharge hose, bad check valve, or bad pump motor, the upper float switch closes as 
the water level in the pump rises. When the upper float switch closes, this activates the 
safety. The safety interrupts power to the icemaker until the upper float switch opens. 
Power is supplied to the pump motor as long as the lower float switch is closed. 
For schematics, see "III.B.2. C-100BAF Series with Optional Drain Pump HS-0248" and 
"III.B.3.e) Optional Drain Pump HS-0248 Safety Shutdown."
2. Float Switch Cleaning
Depending on local water conditions, scale may build up on the float switch. Scale on the 
switch can cause the float to stick. In this case, the float switch should be cleaned and 
checked. 
1) Move the power switch to the "OFF" position, then unplug the unit from the electrical 
outlet. 
WARNING! Moving the power switch to the "OFF" position does not 
de-energize the power supply to the pump. The icemaker must be unplugged to 
de-energize the power supply to the pump.
2) Disconnect the vent hose from the upper rear panel. See Fig. 4.
3) Remove the upper rear panel, then the lower rear panel. 
4) Remove the reservoir cover from the drain pump assembly. See Fig. 5.
5) Leave the float switch assembly connected to the float switch cover and leave the 
float on the shaft. Wipe down the float switch assembly with a mixture of 1 part 
recommended cleaner Hoshizaki "Scale Away" and 25 parts warm water.
6) Rinse the float switch assembly, then replace the reservoir cover in its original position.
Upper Rear Panel
Lower Rear Panel
Vent Hose 
Fig. 4
Fig. 5
Discharge Hose 
Reservoir Cover
Float Switch Assembly