Function Reference — RTSI_Conn
©
 National Instruments Corporation
2-289
NI-DAQ FRM for PC Compatibles
RTSI_Conn
Format
status = RTSI_Conn (deviceNumber, sigCode, trigLine, dir)
Purpose
Connects a device to the specified RTSI bus trigger line.
Parameters
Input
Parameter Discussion
sigCode is the signal code number of the device signal to be connected to the trigger line. 
Signal code numbers for each device type are in the RTSI Bus Trigger Functions section of 
Chapter 3, Software Overview, of the NI-DAQ User Manual for PC Compatibles.
trigLine is the RTSI bus trigger line that is to be connected to the signal.
Range:
0 through 6.
dir is the direction of the connection.
0:
Receive signal (input, receiver) from the RTSI bus trigger line.
1:
Transmit signal (output, source) to the RTSI bus trigger line.
Using This Function
RTSI_Conn
 programs the RTSI interface on the specified deviceNumber such that NI-DAQ 
connects the signal identified by sigCode to the trigger line specified by trigLine. For 
example, if the specified deviceNumber is a non-E Series MIO or AI device, the device 
sigCode is 7, the RTSI trigLine is 3, and the dir is 1, NI-DAQ drives the output produced by 
counter 1 (OUT1) on the specified deviceNumber onto trigger line 3 of the RTSI bus. You 
need to make another call to 
RTSI_Conn
 to program another MIO or AI device (or the same 
device) to receive the OUT1 signal (dir = 0) in order to make use of it.
Name
Type
Description
deviceNumber
i16
assigned by configuration utility
sigCode
i16
signal code number to be connected
trigLine
i16
RTSI bus trigger line
dir
i16
direction of the connection