Справочник Пользователя для Silicon Image SSD-H16G(I)-3500
ATA C
OMMAND
B
LOCK
AND
S
ET
D
ESCRIPTION
SSD-H
XXX
(I)-3500 D
ATA
S
HEET
S
ILICON
S
YSTEMS
P
ROPRIETARY
This document and the information contained within it is confidential and proprietary to SiliconSystems, Inc.
All unauthorized use and/or reproduction is prohibited.
3500H-03DSR
P
AGE
40
F
EBRUARY
2, 2009
Recalibrate — 1Xh
The Recalibrate command sets the cylinder low and high, head number to 0h,
and sector number to 1h in CHS mode. In LBA mode (i.e., LBA = 1), the sector
number is set to 0h.
The Recalibrate command sets the cylinder low and high, head number to 0h,
and sector number to 1h in CHS mode. In LBA mode (i.e., LBA = 1), the sector
number is set to 0h.
Table 40: Recalibrate — 1Xh
Register
D
7
D
6
D
5
D
4
D
3
D
2
D
1
D
0
Feature
X
Sector Count
X
Sector Number
X
Cylinder Low
X
Cylinder High
X
Drive Head
1
LBA
1
Drive
X
Command
1Xh