Справочник Пользователя для Master Bilt TAF-48 ERC2

Скачать
Страница из 18
 
12
High 
Temperature 
Alarm  
ALHi 
High temperature 
setpoint that will 
make the alarm go 
off and the error 
message appear on 
the display 
Range: from – 40  to 83
°
F or –40 to 
23
°
50
°
 F 
 
Important Note: To change from degrees C to F or vice-versa, the user must reprogram all the 
parameters that are related to the temperature. The unit does not convert the parameters 
automatically from degrees F to C or vice-versa. 
 
Example 1 - To adjust the time-of-day 
Press and hold SET for 5 seconds 
Press SET again 
Press UP or DOWN until the correct time appears on the display 
Press SET to accept the new time 
Press DOWN twice to exit the programming mode
 
Example 2 - To set one defrost  a day, at 11:59 PM 
Press and hold SET and DOWN for 10 seconds 
Press DOWN five times to get to go to the Defrost Interval (
dFIn
Press SET to change the parameter 
Press DOWN until 
tdAy
 appears on the display 
Press SET to accept the option 
Press DOWN seven times to go to the Number of Defrosts (
noDF
Press SET to change it 
Press UP or DOWN until 
1
 appears on the display 
Press SET to accept the change 
Press DOWN to go to Defrost Start Time (
dEF1
Press SET to change the time 
Press UP or DOWN until the 
11:59
 PM appears on the display 
Press SET 
Press DOWN ten times to exit the programming level 
 
 
Error Codes  
 
Display Control 
Status 
Er 1 
ERC Fault – software or hardware failure 
Er 2 
ERC Communication Fault – indicates that there is a problem with the display module cable 
Er 3 
Zone Sensor Fault – indicates an open or shorted temperature sensor 
Er 4 
Evaporator Sensor Fault – indicates  an open or shorted evaporator sensor 
Er 5 
ERC Fault – software or hardware failure 
Er 6 
Low Temperature Alarm – indicates that the temperature has dropped below the low alarm setpoint 
Er 7 
High Temperature Alarm – indicates that the temperature has gone above the high alarm setpoint 
Er 8 
Relay and display modules are incompatible 
For Error Codes 1, 2 and 5 cut the power to the unit and correct the problem to reset the 
display. 
For Codes 3 and 4, press the UP or DOWN button on the display to reset the error message. 
If the display still shows the message, the sensor must be replaced. 
The Error Codes 6 and 7 will be automatically reset once the temperature is back within the 
two set points.