Справочник Пользователя для Mitsubishi Electronics FR-V500

Скачать
Страница из 112
99
Model specifications
7
SPECIFICATIONS
7.1 Model specifications
!
!
!
!
 200V class (for use with the dedicated motor [SF-V5R (1500r/min series)])
In
v
e
rt
er
Type FR-V520-[][]K
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
Applied motor capac-
ity (kW)
1.5
2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 
Ou
tp
u
t
Rated capacity (kVA)
(Caution 1)
3.1
4.5
6.9
9.8
13.0
18.7
25.2
30.4
35.8
43.8
58.1
68.5
91.0
Rated current (A)
9.0
13.0
20.0
28.5
37.5
54
72.8
88
103.5
126.5
168
198
264
Overload current rating
(Caution 2)
150% 60s, 200% 0.5s (inverse-time characteristics)
Regen-
erative 
braking 
torque
Maxim um  
value/per-
m issible 
duty
100% torque/3%ED
(Caution 3)
(Caution 7)
100%  
torque/
2% ED
(Caution 3)
(Caution 7)
20% torque/continuous (Caution 7)
Pow
e
r su
ppl
y
Rated input AC 
voltage, frequency
Three-phase, 200V to 220V 50Hz, 200 to 240V 60Hz
Three-phase, 200  to 220V  50H z,  200 to 230V  60H z
Perm issible AC 
voltage fluctuation
170 to 242V 50Hz, 170 to 264V 60Hz
170 to 242V 50Hz, 170 to 253V 60Hz
Perm issible fre-
quency fluctuation
±5%
Instantaneous volt-
age drop im m unity
Operation continues at 165V or higher voltage. If the rated voltage drops to lower than 165V, 15ms operation continues.
Power supply 
capacity (kVA)
(Caution 4)
5.0
6.5
10
14
19
23
33
39
48
57
77
90
123
Protective structure 
(JEM 1030)
Enclosed type (IP20 NEMA1) (Caution 5)
Open type (IP00)
Cooling system
Forced air cooling
Approx. weight (kg)
3.5
3.5
6.0  6.0  6.0  14.0 14.0 21.0 30.0 40.0 40.0 55.0 58.0 
De
d
ic
a
te
d
 m
o
to
r
Motor type
SF-V5R1K
SF-V5R2K
SF-V5R3K
SF-V5R5K
SF-V5R7K SF-V5R11K SF-V5R15K SF-V5R18K SF-V5R22K SF-V5R30K SF-V5R37K SF-V5R45K SF-V5R55K
Rated output (kW)
1.5
2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 
Rated torque (N
####
m)
9.55
14.1
23.6
35.0
47.7
70.0
95.5
118
140
191
235
286
350
Maximum torque 
150% 60s (N
####
m)
14.3
21.1
35.4
52.4
71.6
105
143
176
211
287
353
429
525
Rated speed (r/min)
1500
Maximum speed (r/min)
3000 (Caution 6)
2400
Frame No.
90L
100L
112M
132S
132M
160M
160L
180M
180M
200L
200L
200L
225S
Inertia moment J
 (X10
-4
kg
####
m
2
)
67.5
105
175
275
400
750
875
1725
1875
3250
3625
3625
6850
Noise
80dB or less
85dB or less
90dB or 
less
Cooling fan
Voltage
Single-phase 200V/50Hz
Single-phase 200V/60Hz 
(Caution 9)
Single-phase 
200V/50Hz
Single-phase 200 
to 230V/60Hz
Three-phase 200V/50Hz
Three-phase 200 to 230V/60Hz
Three-
phase 
200V/
50Hz
Three-
phase 
200 V/
60Hz
Input
(50Hz/
60Hz)
36/31W
(0.26/0.22A)
34/28W
(0.17/0.13A)
55/71W
(0.39/0.39A)
100/156W
(0.47/0.53A)
85/
130W
(0.46/
0.52A)
Approx. weight (kg)
24
33
41
52
62
99
113
138
160
238
255
255
320
CAUTION
1. The rated output capacity indicated assumes that the output voltage is 200V.
2. The overload current rating indicated in % is the ratio of the overload current to the rated output cur-
rent of the inverter. For repeated duty, allow time for the inverter and motor to return to or below the
temperatures under 100% load.
3. The short-time rating is 5s.
4. The power supply capacity varies with the value of the power supply side inverter impedance (includ-
ing those of the input reactor and cables).
5. Open type (IP00) when the plug-in option is fitted after removal of the option wiring port cover.
6. You can run the 3.7kW or less motor at the maximum speed of 3600r/min, consult us when you want
to run the motor at higher than 3000r/min.
7. For the 1.5K to 15K capacities, using the optional high-duty brake resistor (FR-ABR) will achieve the
performance of 100% torque/10%ED.
8. If the motor is one rank lower in capacity than the inverter, it can be used by setting Pr. 80 "motor
capacity" and Pr. 81 "number of motor poles". Other manufacturers’ motors and special motors can
be used by performing online auto tuning.
9. The power supply fluctuation range is 200V ±10%.