Справочник Пользователя для Mitsubishi Electronics FR-V500

Скачать
Страница из 112
101
Common specifications
7.2 Common specifications
In
ve
rt
er
C
o
ntr
o
l sp
ec
ifi
cat
io
ns
Control system
Soft-PWM control or high carrier frequency sine-wave PWM control can be selected.
Vector control, or V/F control can be selected.
Control mode
Speed control, torque control, position control
Speed setting 
resolution
Analog input 0.03% of the maximum set speed
Digital input
0.003% to the maximum setting (minimum setting 0.1r/min)
Acceleration/deceleration time 0 to 3600 s (0.1 s increments)
Acceleration/deceleration 
pattern
Linear, S pattern (3 types) or backlash compensation acceleration/deceleration can be selected.
Torque restriction level
Torque restriction value can be set (0 to 400% variable)
Inpu
t s
ign
al
s
Analog setting signal
Terminal 
No.
Setting Range
Speed Control
Torque Control
2
0 to 10V (resolution 0.03%) Main speed setting
Speed restriction
1
0 to ±1 0V  
(resolution 0.05% )
A uxiliary speed setting/m agnetic flux 
com m and/regenerative torque restriction
Speed restriction compensation/
magnetic flux command/forward/
reverse rotation speed restriction
(analog polarity switchover speed 
restriction)
3
0  to ±1 0V  (reso lutio n 0 .05% ) Torqu e re stric tion /Torque  bias
Torque command
Option (FR-V5AX)
6
0 to ±1 0V  
(resolution 0.003 % )
M ain spe ed s ettin g (a t th is tim e, 
te rm in al 2  is invalid)/torqu e re stric tion
Speed restriction (at this time, terminal 
2 is invalid)/Torque command (at this 
time, terminal 3 is invalid)
Contact signal
3 fixed function terminals
F orw a rd rotation  com m an d, a larm  res et,  exte rnal the rm al rela y
5 function terminals
Selection can be m ade from  reverse rotation com m and, m ulti-speed setting (m ax. 15 
speeds), rem ote setting, jog operation (C aution 1), second function selection, third 
function selection, output stop, start signal self-holding, pre-excitation, control m ode 
sw itchover, torque restriction selection, S pattern sw itchover, PID control term inal, 
orientation com m and, break opening com pletion signal, PU  operation/external operation 
sw itchover, torque bias selection 1, torque bias selection 2, P control selection, servo on, 
H C  connection, and PU/external interlock.
Option (FR-V5AX)
6 multi-function terminals
Ou
tp
u
t sig
n
a
ls
Contact signal
1 changeover contact
(230VAC 0.3A, 30VDC 0.3A)
Selection can be made from inverter running, inverter running 2, up to speed, 
instantaneous power failure (undervoltage), speed detection, second speed 
detection, third speed detection, PU operation mode, overload alarm, 
regenerative brake prealarm, electronic thermal relay prealarm, output current 
detection, zero current detection, PID lower limit, PID upper limit, PID forward/
reverse rotation output, operation ready, operation ready 2, brake opening 
request, fan fault output, heatsink overheat prealarm, orientation in-position, 
forward rotation output, reverse rotation output, low speed output, torque 
detection, regenerative status output, minor fault output, minor fault output 
2,alarm output, maintenance timer output, remote output, output speed 
detection, second (third) output speed detection, in-position and trace status.
Open collector signal
3 multi-function terminals
Option (FR-V5AY)
3 multi-function terminals
Option (FR-V5AM)
1 multi-function terminal
Option (FR-A5AY))
7 multi-function terminals
Analog output
0 to ±10V 12 bits ×1CH
0 to 10V 12 bits ×1CH
Selection can be made from speed, output current, output voltage, preset 
speed, output frequency, motor torque, converter output voltage, regenerative 
brake duty, electronic overcurrent protection load factor, output current peak 
value, converter output voltage peak value, load meter, motor exciting current, 
motor output, reference voltage output, torque command, torque current 
command and torque monitoring.
Option (FR-A5AY)
0 to 10V 10 bits × 1CH
0 to 20mA 10 bits × 1CH
PLG pulse output
option (FR-V5AY)
A phase, B phase, Z phase (A and B phases can be divided)
Open collector/differential line driver.
Operational functions
Maximum/minimum speed setting, speed jump, external thermal relay input selection, polarity reversible operation, 
override function, automatic restart operation after instantaneous power failure, forward/reverse rotation 
prevention, operation mode selection, offline auto tuning function, online auto tuning function, easy gain tuning, 
computer link operation, remote setting, brake sequence, second function, third function, multi-speed operation, 
coasting to stop, power failure stop, PID control, speed feed forward, model adaptive speed control, master/slave, 
torque bias, 12-bit digital command (FR-A5AX option), 
16-bit digital command (FR-A5AH option), pulse train input 
(FR-A5AP option), motor thermistor interface (FR-V5AX option)
Dis
p
la
y
Parameter unit
(FR-DU04
-1
/FR-PU04V)
Selection can be made from speed, output current, output voltage, preset speed, output frequency, motor torque, 
converter output voltage, regenerative brake duty, electronic overcurrent protection load factor, output current 
peak value, converter output voltage peak value, input terminal status (Caution 4), output terminal status (Caution 
4), load meter, motor exciting current, position pulse, cumulative operation time, actual operation time, motor load 
factor, torque command, torque current command, feedback pulse, motor output, trace status.
Alarm definition
Alarm definition is displayed when protective function is activated. 8 past alarm definitions are stored. (Only 4 
alarm definitions are displayed on the operation panel.)
Protective functions
O vercurrent shut-off (acceleration, deceleration, constant speed), regenerative overvoltage shut-off (acceleration, deceleration, 
constant speed), undervoltage, instantaneous pow er failure, overload shut-off (electronic therm al relay), brake transistor alarm  
(C aution 2), earth (ground) fault current, pow er output short circuit (12/24VDC /operation panel), stall prevention, external 
therm al relay, heatsink overheat, fan fault, option alarm , param eter error, PU  disconnection, encoder no-signal, speed deviation 
large, overspeed, position error large, C PU error, encoder phase error, output phase failure, retry count excess, brake sequence 
error
E
n
vi
ro
n
m
en
t
Ambient temperature
-10C to +50°C(non-freezing)
Ambient humidity
90%RH or less (non-condensing)
Storage tem perature
 (C au tion 3)
-20 to +65°C 
Atmosphere
Indoor use. (No corrosive gas, flammable gas, oil mist, dust and dirt)
Altitude, vibration
Maximum 1,000m above sea level, 5.9m/s
2
 or less (compliant with JIS C 0040)
De
d
ic
a
te
d
 
mo
to
r
Ambient temperature, humidity
-10 to +40°C (non-freezing), 90%RH or less (non-condensing)
Structure
Totally enclosed forced draft system
Detector
PLG 2048P/R, A phase, B phase, Z phase +12VDC power supply
Equipment
PLG, thermal protector, fan
Insulation
Class F
Vibration rank
V10
De
d
ic
a
te
d
 
P
L
G
 cab
le
Resolution
2048 pulse/rev
Power supply voltage
12VDC±10%
Current consumption
90mA
Output signal form
A, B phases (90° phase shift) Z phase: 1 pulse/rev
Output circuit
Complimentary (constant voltage output matched by emitter follow)
Output voltage
"H" level: Power supply voltage 9V or more (I
OH
: -20mA), "L" level: Power supply voltage 3V or less (I
OL
: 20mA
)
CAUTION
1. Jog operation may also be performed from the operation panel (FR-DU04
-1
) or the parameter unit (FR-
PU04V).
2. Not provided for the FR-V520-18.5K to 55K, FR-V540-18.5K to 55K that do not have a built-in brake circuit.
3. Temperature applicable for a short period in transit, etc.
4. Not provided for the operation panel (FR-DU04
-1
).