Operation selection function 2 (Pr. 65 to Pr. 79)
P
A
RAMETERS
3
3.11.5 Reset selection/disconnected PU detection/PU stop selection
 
(Pr. 75
)
<Setting>
(1) Restarting method when stop was made by inputting 
 from the control panel
 
(Method of restarting from 
 indication)
1)After the motor has decelerated to a stop, turn off the STF or STR signal.
2)Press 
 twice* to display 
.
(*For monitor screen)
.......
 Refer to the Instruction Manual (basic) for details of the monitor display provided 
by pressing 
.
3)Press .
4)Turn on the STF or STR signal.
You can select the reset input acceptance, PU (FR-DU04-
1
/FR-PU04V) connector disconnection detection 
function and PU stop function.
z Reset selection:
You can select the reset function input (RES signal) timing.
z Disconnected PU detection: When the disconnection of the PU (FR-DU04-
1
/FR-PU04V) from the inverter for 
more than 1s is detected, the inverter outputs an alarm code (E.PUE) and 
comes to an alarm stop.
 
The motor decelerates to a stop when the PU is disconnected during PU jog 
operation with Pr. 75 set to any of "0, 1, 14, 15"(operation is continued if the PU 
is disconnected).
z PU stop selection:
When an alarm etc. occurs in any operation mode, you can stop the motor from 
the control panel by pressing 
.
Parameter
Name
Factory 
Setting
Setting Range
Remarks
75
Reset selection/disconnected PU 
detection/PU stop selection
14
0 to 3, 14 to 17
Extended mode
Pr. 75 
Setting
Reset Selection
Disconnected PU
Detection
PU Stop Selection
0
Reset input is always enabled.
If the PU is disconnected, 
operation will be continued 
as-is.
The PU stop key is invalid. 
 
input is valid only in the PU or combined 
operation mode (Pr. 79 = "4").
1
Reset input is enabled only when the 
protective function is activated.
2
Reset input is always enabled.
When the PU is 
disconnected, the inverter 
output is shut off.
3
Reset input is enabled only when the 
protective function is activated.
14
Reset input is always enabled.
If the PU is disconnected, 
operation will be continued 
as-is.
 input decelerates the motor 
to a stop in any of the PU, external and 
communication operation modes.
15
Reset input is enabled only when the 
protective function is activated.
16
Reset input is always enabled.
When the PU is 
disconnected, the inverter 
output is shut off.
17
Reset input is enabled only when the 
protective function is activated.
CAUTION
When Pr. 79 = "3", press 
 three times to display 
. Then press 
 and proceed to 3).
REMARKS
• If the reset signal (RES) is provided during operation, the inverter shuts off its output while it is reset, the internal thermal 
integrated value of the electronic thermal relay function and the number of retries are reset, and the motor coasts.
• The Pr. 75 value can be set any time. This value does not return to the initial value even if parameter (all) clear is executed.
• When the motor is stopped from the PU, 
 and 
 are displayed alternately. An alarm output is not provided.
speed
torque
position
STOP
RESET
STOP
RESET
STOP
RESET
STOP
RESET
MODE
MODE
MODE
SET