166
Control system function (Pr. 374)
3.28 Control system function (Pr. 374)
3.28.1 Overspeed detection (Pr. 374
)
z Excess of the motor speed over the overspeed detection level results in E.OS, stopping the output. 
This function is enabled only during speed control, torque control or position control.
Parameter
Name
Setting Range
Factory Setting
Remarks
374
Overspeed detection level
0 to 4200r/min
3450r/min
Extended mode
Pr. 380 to Pr. 383
Refer to Pr. 29 (page 89).
Pr. 393, Pr. 396 to Pr. 399
Refer to Pr. 350 (page 159).
speed
torque position
ABC
Motor speed 
Time
E.OS
Coast to stop
ON
Pr. 374