Справочник Пользователя для Mitsubishi Electronics FR-V540-1.5K to 55K

Скачать
Страница из 232
181
Additional functions (Pr. 851 to Pr. 865)
P
A
RAMETERS
3
3.34.3 Excitation ratio (Pr. 854
)
  
3.34.4 Notch filter (Pr. 862, Pr. 863
)
z
Pr. 862 "notch filter frequency"
z
Pr. 863 "notch filter depth"
z Decrease the excitation ratio when you want 
to improve efficiency under light load. (motor 
magnetic noise decreases) Note that the rise 
of output torque becomes slow if excitation 
ratio is decreased.  This function is 
appropriate for applications as machine tools 
which repeat rapid acceleration/deceleration 
up to high speed.
 
Parameter
Name
Factory Setting
Setting Range
Remarks
854
Excitation ratio
100%
0 to 100%
Extended mode
REMARKS
When "1" (magnetic flux command from the terminal 1) is set in Pr. 868 "terminal 1 function assignment", this Pr. 854 setting is 
made invalid.
Pr. 859
Refer to page 123
You can reduce the response level of speed control in the resonance frequency band of the mechanical 
system to avoid mechanical resonance.
Parameter
Name
Setting Range Increments Factory Setting
Remarks
862
Notch filter frequency
0 to 31
1
0
0: Function 
invalid
Extended mode
863
Notch filter depth
0 to 3
1
0
Pr. 862
Setting
Frequency
Pr. 862
Setting
Frequency
Pr. 862 
Setting
Frequency
Pr. 862
Setting
Frequency
0
invalid
8
140.6
16
70.3
24
46.9
1
1125.0
9
125.0
17
66.2
25
45.0
2
562.5
10
112.5
18
62.5
26
43.3
3
375.0
11
102.3
19
59.2
27
41.7
4
281.3
12
93.8
20
56.3
28
40.2
5
225.0
13
86.5
21
53.6
29
38.8
6
187.5
14
80.4
22
51.1
30
37.5
7
160.7
15
75.0
23
48.9
31
36.3
Pr. 863 Setting
Depth (Gain)
0
deep (-40dB)
1
 (-14dB)
2
 (-8dB)
3
sharow (-4dB)
CAUTION
z If you do not know the mechanical resonance frequency, decrease notch frequency gradually from the highest 
value.  The point at which the smallest vibration is generated is the notch freqeuncy setting.
z The notch filter with deeper depth has an effect on minimizing mechanical resonance. However, large vibration 
may be generated adversely due to substantial phase delay.
z Machine characteristic can be obtained beforehand with machine analyzer by setup software. Necessary 
notch frequency can be determined from this.
speed
torque
position
Excitation
ratio
[%]
100
(Factory setting)
Pr. 854
setting
0
100
Load[%]
speed
position