Справочник Пользователя для Mitsubishi Electronics FR-V540-1.5K to 55K

Скачать
Страница из 232
183
Display function (Pr. 867)
P
A
RAMETERS
3
3.35 Display function (Pr. 867)
3.35.1 DA1 output response level adjustment (Pr. 867
)
3.36 Terminal function assignment (Pr. 868)
3.36.1 Terminal 1 function assignment (Pr. 868
)
<Terminal 1 function according to control>
* The function is changed to main speed according to the Pr.73 setting with which override, polarity reversible 
function, etc. can be selected. (Refer to page 113.)
You can adjust the response level of the output voltage of the output signal DA1.
Parameter
Name
Factory Setting
Setting Range
Remarks
867
DA1 output filter
0.05s
0 to 5s
Extended mode
The terminal 1 can be multi-functioned.
Parameter
Name
Factory Setting
Setting Range
Remarks
868
Terminal 1 function 
assignment
0
0, 1, 2, 5, 9999
Extended mode
Pr. 868 
Setting
Terminal 1 
Function under 
Speed Control
Terminal 1 Function 
under Torque Control
Terminal 1 
Function under 
Position Control
Bias/Gain Setting
Remarks
0
(factory 
setting)
Speed setting 
auxiliary
Speed limit auxiliary
No function
Pr. 902 "speed setting 
 
terminal 2 bias"
Pr. 903 "speed setting 
 
terminal 2 gain"
1
Magnetic flux 
command
Magnetic flux command
Magnetic flux 
command
Pr. 919 "terminal 1 bias 
(torque/magnetic flux)"
Pr. 920 "terminal 1 gain 
(torque/magnetic flux)"
2
Regenerative 
torque limit
No function
Regenerative 
torque limit
Pr. 919 "terminal 1 bias 
(torque/magnetic flux)"
Pr. 920 "terminal 1 gain 
(torque/magnetic flux)"
Setting can be 
made when 
Pr. 810 = 1.
5
No function
Forward/reverse rotation 
speed limit
(analog polarity 
switchover speed limit)
No function
Pr. 917 "terminal 1 bias 
(speed)"
Pr. 918 "terminal 1 gain 
(speed)"
9999
No function
No function
No function
No function
No function
REMARKS
Refer to page 190 for bias/gain settings.
speed
torque position
speed
torque
position