Справочник Пользователя для Mitsubishi Electronics FR-F740P

Скачать
Страница из 410
161
4
4.12.5 How to calibrate the terminal FM when using the operation panel (FR-DU07)
Perform the following procedure to calibrate terminal FM using the operation panel FR-DU07. Refer to page 159 for
the details of parameters. 
REMARKS
⋅ Calibration can also be made for external operation. Set the frequency in External operation mode, and make calibration in
the above procedure.
⋅ Calibration is available even during operation.
⋅ For the operating procedure using the parameter unit (FR-PU04/FR-PU07), refer to the parameter unit instruction manual.
♦ Parameters referred to 
C0(Pr.900) FM terminal calibration  
Refer to page 159
C1(Pr.901) AM terminal calibration 
 Refer to page 159
Press        to return to the               indication (step 8).
13. 
Press        .   Setting is complete.
2. 
Press          to choose the parameter 
      setting mode.
3. 
Flicker...Parameter setting complete!!
Flicker...Parameter setting complete!!
Analog indicator
6. 
Press         to set.
7. 
Turn          until                appears.
5.
 Turn           to change it
     to the setting value of "     ".
4.
 Press         to read the present set value.
     "             " (initial value) appears.
1.
Confirmation of the RUN indicator and 
     operation mode indicator
8. 
Press         to display              .
10.
 Press          to enable setting.
11. 
If the inverter is at a stop, (press
                  or         ) to start the inverter.
        (Motor needs not be connected.)
12.
 Turn          to adjust the indicator needle 
         to the desired position.
(    )   )
By turning         , you can read another parameter.
+
-
The parameter 
number read 
previously appears.
(When 
Pr. 54=1)
Press        twice to show the next parameter (             ).
Display
Operation
9.
Turn          until                appears.
    Set to
C0 FM terminal calibration.
C0 to C7 
setting 
is enabled.
The monitor set to 
Pr. 54 FM terminal 
function selection is displayed.