Справочник Пользователя для Mitsubishi Electronics C6/C64

Скачать
Страница из 173
4. CONTROL UNIT CONNECTIONS 
4.16    Control Unit Connector Pin Assignments 
 
 
I - 47 
 
 


3
 
I/O 
I/O 
 
TXRX1
TXRX1*
GND 
Remote I/O 
RIO-M 
<Cable side connector type>
Connector  
1-178288-3 
Contact  
1-175218-2 
Recommended maker : Tyco Electronics AMP 
 
 


3
 
I/O 
I/O 
 
TXRX2
TXRX2*
GND 
Remote I/O 
RIO-M/S 
<Cable side connector type>
Connector   : 
1-178288-3 
Contact  : 
1-175218-2 
Recommended maker : Tyco Electronics AMP 
 
 

2
 
 
GND 
+3.6V
Battery 
BAT 
<Cable side connector type>
The connector and contact depend on the
battery. 
 
 


3
 
 
 
+24V
GND
FG 
+24V input 
DC24VIN 
<Cable side connector type>
Connector  
:  1-178288-3 
Contact  
1-175218-5 
Recommended maker : Tyco Electronics AMP 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 CAUTION 
 
  Do not apply a voltage other than that specified in this manual onto the connector. 
Failure to observe this could lead to rupture or damage. 
 
  Incorrect connections could cause device damage, so always connect the cables to the 
designated connectors.