Справочник Пользователя для Mitsubishi Electronics C6/C64

Скачать
Страница из 173
5. CONNECTION OF COMMUNICATION TERMINAL 
5.2  Connection of Power Supply 
 
 
-
 49
 
5.2  Connection of Power Supply 
 
The 24VDC must be supplied to the communication terminal. 
Prepare a stabilized power supply that satisfies the following conditions. 
The 9-type CRT type requires 100VAC for the CRT power supply. 
 
Type 
FCUA-LD100/ 
LD10 
FCU6-DUT32 
FCUA-CT100/ 
CT120/KB10 
Power voltage 
24VDC
±5% 
Ripple 
±5% (p-p) 
Instantaneous power failure 
tolerable time 
Follows specifications of 24VDC power supply being used 
Current consumption 
24VDC, 0.9A 24VDC, 
0.9A 24VDC, 
0.6A 
 
5.2.1  Connection of Power Supply to 7.2-type Monochrome LCD 
(FCUA-LD100/FCUA-LD10+KB20) 
 
Supply 24VDC to the CR01 connector on the rear of the LCD. 
 
 
 
 
 
LCD 
J1
J2
CR03
CR02
CR05
CR06
CNZ24
CR01
[FCUA-LD100/LD10+KB20 rear side] 
FG 3
0V 2
24VDC(+) 1
R220 cable 
24VDC(+)
0V 
 
FG 
Stabilized 
power supply 
FG
 
Y
 
 
 
 CAUTION 
 
  Separate the signal wire from the drive line/power line when wiring. 
 
  Do not apply voltages other than those indicated in this manual on the connector. Doing 
so may lead to destruction or damage. 
 
 Incorrect connections may damage the devices, so connect the cables to the specified 
connectors. 
Recommended adaptive connector  
(Enclosed with FCUA-LD100/FCUA-LD10+KB20) 
Connector : 2-178288-3 
Contact 
: 1-175218-5 (tin plated) (Tyco Electronics AMP)