Table  4-6    E2400 10x Array Module Power Requirements
Item
Unit of Measure
Requirement
Circuit Breaker 
Slow-blow Fuse
10 A per Power Supply
AC Power
Low Range
High Range
Nominal Voltage
90 to 136 VAC
198 to 264 VAC
Frequency
50 to 60 Hz
50 to 60 Hz
Idle Current
3.39 A
1.45 A
1
Maximum Operating Current 
3.53 A
1.50 A
1
Maximum Surge Current
(10-drive spin up)
5.19 A
2.10 A
1
1
Typical current at 240 VAC, 60 Hz at 0.70 power efficiency, 0.99 power factor.
Table  4-7    E2400 14x Array Module Power Requirements
Item
Unit of Measure
Requirement
Circuit Breaker 
Slow-blow Fuse
10 A per Power Supply
AC Power 
Low Range
High Range
Nominal Voltage 
90 to 136 VAC
198 to 264 VAC
Frequency
50 to 60 Hz
50 to 60 Hz
Idle Current 
2.9 A
1
1.3 A
2
Maximum Operating 
Current
3.3 A
1
1.4 A
2
Maximum Surge Current
(14-drive spin up)
5.9 A
1
2.4 A
2
1
Typical voltage: 100 V AC, 60 Hz at 79% power supply efficiency and 0.99 power factor.
2
Typical voltage: 240 V AC, 60 Hz at 81% power supply efficiency and 0.92 power factor.