Functions
3.7 System monitoring
M200D AS-Interface Basic
Manual, 03/2009, A5E01668085-01
Manual, 03/2009, A5E01668085-01
37
Connector monitoring
Line-side connector monitoring can be deactivated via the DIP switch.
For more information, see Parameterization via local setting (Page 72).
For more information, see Parameterization via local setting (Page 72).
Response when connector is unplugged
When the connector is unplugged, the motor starter outputs a group fault.
Settings
Device parameter
Default setting
Setting range
Connector monitoring
Line side
•
Deactivated
•
Line side
3.7.5.2
Motor connector
The "connector monitoring" function is only valid for the infeed connector.
A connector monitoring function for the motor connector can be logically combined with the
A connector monitoring function for the motor connector can be logically combined with the
thermistor cable and/or thermistor evaluation function.
If a motor is operated without a thermistor, you can activate thermistor monitoring
If a motor is operated without a thermistor, you can activate thermistor monitoring
(thermoclick) and use it to monitor the connector by means of a wire jumper on the motor
terminal board or in the motor connector.
Note
The "overload" message must be interpreted to mean that the motor connector has been
The "overload" message must be interpreted to mean that the motor connector has been
unplugged.