10 - 15 
MELSEC-Q
10   HIGH-LEVEL POSITIONING CONTROL 
 
10.3.7 Repeated start (FOR condition) 
In a "repeated start (FOR condition)", the data between the " block start data" in which 
"5: FOR condition" is set in "   Da.13   Special start instruction" and the " block start 
data" in which "6: NEXT start" is set in "   Da.13   Special start instruction" is repeatedly 
executed until the establishment of the conditions set in the "condition data". 
Conditional judgment is carried out as soon as switching to the point of "6: NEXT start" 
(before positioning of NEXT start point). 
(The "condition data" designation is set in "   Da.14   Parameter" of the " block start 
data" in which "5: FOR condition" is set in "   Da.13   Special start instruction".) 
 
Section [2] shows a control example where the " block start data" and "positioning 
data" are set as shown in section [1].   
 
[1]   Setting examples 
 
(1)      Block start data setting example 
 
Axis 1 block 
start data 
 Da.11 
 
Shape 
 Da.12 
 
Start data No.
 Da.13 
 
Special start 
instruction 
 Da.14 
 
Parameter 
1st point 
1: Continue 
5: FOR condition 
2nd point 
1: Continue 
10 
0: Block start 
– 
3rd point 
0: End 
50 
6: NEXT start 
– 
 
 
 
 
 
 
 
 
 
 
  The "condition data Nos." have been set in "   Da.14   Parameter". 
 
(2)      Positioning data setting example 
 
Axis 1 position-
ing data No. 
 Da.1 
 
Operation pattern 
01: Continuous positioning control
01: Continuous positioning control
3 00: 
Positioning 
complete 
 
 
10 
11: Continuous path control 
11 00: 
Positioning 
complete 
 
 
50 
01: Continuous positioning control
51 00: 
Positioning 
complete 
 
 
 
[2]   Control examples 
The following shows the control executed when the " block start data" of the 1st 
point of axis 1 is set as shown in section [1] and started.   
 
<1>  Execute axis 1 "Positioning data No. 1, 2, 3, 10, 11". 
 
<2>  Execute the conditional judgment set in axis 1 "Condition data No.5".  1 
  Conditions not established 
  Execute "Positioning data No. 50, 51". 
Go to <1> 
 Conditions established    Execute "Positioning data No.50, 51" and 
complete the positioning. 
 
1: Conditional judgment is carried out as soon as switching to NEXT start point 