Appendix - 42 
MELSEC-Q
APPENDICES 
 
Appendix 4.4 Connection example of QD75D N and MR-C    A (Differential driver)
5
 
 
PULSE F+
15
PULSE F-
16
PULSE R+
17
PULSE R-
18
CLEAR
13
CLEAR COM 14
PG024
8
PG0 COM
10
DOG
3
FLS
1
RLS
2
STOP
4
COM
7
A19
B19
A20
B20
PULSER A+
QD75D   N
PP
PG
NP
NG
CR
SG
V+
OP
SD
LSP
LSN
9
10
7
8
13
12
1
4
11
15
14
5V
A
B
0V
+5V
5G
Servo ON
*3
*3
*1
Within 10m *4
CN1
NF
MC
L1
L2
U
V
W
U
V
W
E
SM
EMG
CN2
TE1
READY
CHG
COM
PULSER A-
PULSER B+
PULSER B-
11
5
6
SON
ALM
V24
2
20
17
C
P
Regenerative resistor is 
an external option.
Servo READY
Fault
+
-
PULSE F
15
PULSE COM 16
PULSE COM 18
PULSE R
17
PP
9
SG
12
NP
7
CN1
RDY COM
12
Configure a sequence to turn OFF the MC 
at alarms and emergency stops.
Power supply 
Single-phase 200VAC 
(A type) or 
single-phase 100VAC 
(A1 type)
Upper limit
Stop
External command
*2
*2
Near-point dog
Lower limit
Forward run stroke end
Reverse run stroke end
RA1
Electromagnetic 
brake
24VDC
Cutoff when a servo ON signal turns 
OFF and an alarm signal turns ON.
HC-PQ series 
motor
MR-C   A 
or 
MR-C   A1
Manual pulse 
generator
MR-HDP01
24V, 0.2A or higher
24V power 
supply
When connecting an open collector, 
make connection as shown below.
QD75P    N
Detector
 
 
REMARK 
(1) It is recommended to make differential driver connection since differential driver connection is more excellent than 
open collector connection in max. output pulse and max. connection distance between servos. (Refer to Section 
3.1 "Performance specifications".) 
(2)  1: The logic for each I/O terminal can be changed with "   Pr.22   Input signal logic selection" and "   Pr.23    
Output signal logic selection" in detailed parameters 1. (Negative logic is used for all terminals in the example 
above.) 
(3)  2: The  QD75D N upper limit (FLS) and lower limit (RLS) are used in the OPR retry function. Set these signals 
inside the servo amplifier limit switches. 
(4)  3: These are limit switches for the servo amplifier (for stop). 
(5)  4: This indicates the distance between the QD75D N and servo amplifier. 
(6)  5: Use the same logic (positive logic/negative logic) for the QD75D N and servo amplifier. The QD75D N is 
initially set to negative logic.