3. I/O 
PARAMETERS 
3.2 
I/O Device Parameters 
II - 17 
 
3.2  I/O Device Parameters 
Parameters for up to five types of input/output devices can be set in DEV <0> to <4>. 
Item 
Contents 
Setup range (unit) 
9101  DEVICE NAME 
Set the device name corresponding to the device 
No. 
Set a simple name for quick identification. 
Use alphabet 
characters‚ numerals 
and symbols to set a 
name within 3 
characters. 
9102  BAUD RATE 
Set the serial communication speed. 
0: 19200  (bps) 
1:   9600   
2: 4800 
3: 2400 
4: 1200 
5: 600 
6: 300 
7: 150 
9103  STOP BIT 
Set the stop bit length used in the start-stop system. 1:  1  (bit) 
2:  1.5 
3:  2 
9104  PARITY CHECK 
Specify whether to add the parity check bit to the 
data during communication. 
0:  Parity bit not added
1:  Parity bit added 
9105  EVEN PARITY 
Specify the odd or even parity when it is added to 
the data. 
0: Odd parity 
1: Even parity 
9106  CHR. LENGTH 
Set the length of the data bit. 
0:  5  (bit) 
1:  6 
2:  7 
3:  8 
9107  Terminator type 
The code to terminate data reading can be selected. 0 and 3: EOR 
1 and 2: EOB or EOR
9108  HAND SHAKE 
Specify the transmission control method.  
The method will be no procedure if a value except 1 
to 3 is set. 
1: RTS/CTS method 
2:  No procedure (No 
handshaking)  
3:  DC code method 
9109  DC CODE PARITY 
Specify the DC code when the DC code method is 
selected. 
0:  No parity to DC 
code (DC3 = 13H)
1:  DC code with parity 
(DC3 = 93H) 
9111 DC2/DC4 OUTPUT 
Specify the DC code handling when outputting data 
to the output device. 
DC2 / DC4 
0:  None / None 
1:  Yes / None 
2:  None / Yes 
3:  Yes / Yes 
9112  CR OUTPUT 
Specify whether to insert the <CR> code just before 
the EOB (L/F) code during output. 
0:  Do not add 
1: Add