7. SERVO 
PARAMETERS 
7.5 Supplement 
 
II - 220 
7.5.2 Electronic gears 
The servo drive unit has internal electronic gears. The command value from the NC is converted into a 
detector resolution unit to carry out position control. The electronic gears are single gear ratios calculated from 
multiple parameters as shown below. However, each value (ELG1, ELG2) must be less than 32767. 
If the value overflows, the initial parameter error (alarm 37) or error parameter No.2301 will be output. 
If an alarm occurs, the mechanical specifications and electrical specifications must be revised so that the 
electronic gears are within the specifications range. 
 
<For semi-closed loop control> 
ELG1 
PC2×RNG1 
Reduced fraction of 
ELG2 
PC1×PIT×IUNIT 
(reduced fraction) 
 
 
IUNIT = 2/NC command unit (
µm) 
 
1
µm : IUNIT = 2,  0.1µm : IUNIT = 20 
 
 
When the above is calculated, the following conditions must be satisfied. 
 ELG1 
≤ 32767 
 ELG2 
≤ 32767 
 
 
<For full-closed loop control> 
PGNX 
PC2×RNG2×PGN1
Reduced fraction of 
PGNY 
PC1×RNG1×30 
(reduced fraction)
 
 
 
When the above is calculated, the following conditions must be satisfied. 
 PGNX 
≤ 32767 
 PGNY 
≤ 32767 
 
 And, 
PGNXsp 
PC2×RNG2×PGN1sp 
Reduced fraction of
 
PGNYsp 
PC1×RNG1×30 
(reduced fraction)
 
 
 
When the above is calculated, the following conditions must be satisfied. 
 PGNXsp 
≤ 32767 
 PGNYsp 
≤ 32767