1. 
LIST OF ALARMS 
1.5 System 
Alarms 
I - 28 
 
Message Details 
Remedy 
Z59 TIME 
CONSTANT 
Acceleration and deceleration time 
constants are too large. 
(This alarm is output at the same 
time as "T02 FEED HOLD 0206.") 
•  Increase the value specified as the #1206 
G1bF parameter. 
•  Decrease the value specified as the 
#1207 G1btL parameter. 
•  Lower the feedrate. 
 
 
  CAUTION  
 
 If the battery low warning is issued, save the machining programs, tool data and parameters in 
an input/output device, and then replace the battery. When the battery alarm is issued, the 
machining programs, tool data and parameters may be destroyed. Reload the data after 
replacing the battery. 
 
  Do not replace the battery while the power is ON. 
 
  Do not short circuit, charge, heat, incinerate or disassemble the battery. 
 
  Dispose of the spent battery following local laws. 
 
Note 1: Temperature warning  
If the alarm is displayed when an overheat alarm is detected‚ the overheat signal will be output 
simultaneously. If the machine is in automatic operation‚ the operation will be continued‚ but 
restarting will not be possible after resetting or stopping with M02/M30. (Starting will be possible 
after block stop or feed hold.) The alarm will be reset and the overheat signal will turn OFF when 
the temperature drops below the specified temperature.  
Z53  TEMP. OVER 
000x 
 
 
 
   
↑ 
 
 
 
0001  :  The temperature in the controller is high. 
 
 
 
0002  :  The temperature around the communication terminal 
 
 
 
 
(setting and display unit) is high. 
 
 
 
0003  :  The temperature in the controller and around the communication 
 
 
 
 
terminal (setting and display unit) is high. 
 
The ambient temperature must be lowered immediately when a "Z53 TEMP.OVER" alarm occurs‚ but if 
machining must be continued‚ the alarm can be invalidated by turning the following parameter OFF. 
 
 7 6 5 4 3 2 1 0 
PLC parameter bit selection #6449 
 
 
Communication terminal 
(setting and display unit) 
0: Detection invalid 
Controller 