12. POSITION 
SWITCH 
12.2 
Canceling the Position Switch 
II - 306 
 
Rotation axis 
Setting of dog1 and dog2 
dog1, dog2 position 
Description 
dog1 
< dog2 
dog2 dog1 
(Example) 
dog1 =
30.000
dog2 = 330.000
 
 
A signal is output 
between dog1 and 
dog2. 
 
dog1 dog2 
(Example) 
dog1 = -30.000
dog2 =
30.000
 
   
     
 
A signal is also output 
when dog1 is negative. 
dog1 
> dog2 
dog1 dog2 
(Example) 
dog1 = 330.000
dog2 =
30.000
 
     
 
A signal is output 
between dog2 and 
dog1. 
⏐dog1 − dog2⏐ ≥ 360 
dog2 dog1 
(Example) 
dog1 =
30.000
dog2 = 390.000
 
 
A signal is kept output 
when the difference 
between dog1 and dog2 
exceeds 360 degrees. 
 
12.2  Canceling the Position Switch 
To cancel the position switch‚ enter the number (#75 1) of the position switch to be canceled in # ( ) of the 
setting field‚ enter a slash "/" in DATA ( )‚ then press the INPUT key. This deletes the axis name for the 
specified position switch‚ thus invalidating the position switch. 
The data specified for <dog1> and <dog2> are still stored in memory. To validate the position switch again‚ 
therefore‚ it is enough to specify the axis name only.