Справочник Пользователя для Mitsubishi Electronics E60

Скачать
Страница из 415
13.  AUXILIARY AXIS PARAMETER 
 
II - 308 
 
No. Name 
Details 
Setting 
range 
Default 
value 
ATU 
Auto-tuning 
Set the adjustment of the auto-tuning. Do not set values without a description. 
 
0 1 0 2 (Default 
setting 
value) 
 
 
 
 
 
 
 
 
 
 
Setting 
value 
Details 
 
 
 
 
Low response (low-rigidity loads, loads 
which easily vibrate) 
    
Standard 
setting 
value 
    
Standard 
setting 
value 
    
Standard 
setting 
value 
 
 
 
 
High response (high-rigidity loads, loads 
which do not easily vibrate) 
 
 
 
 
 
 
 
 
 
 
Setting 
value 
Details 
    
Standard 
 
 
 
 
Large friction amount (set the position loop 
gain slightly lower) 
 
 
 
 
 
 
 
 
 
 
Setting 
value 
Details 
 
 
 
 
Only auto-tuning PG2, VG2, VIC, and GD2.
 
 
 
 
Only auto-tuning PG1, PG2, VG1, VG2, 
VIC, and GD2 (total gain). 
(Standard setting) 
    
No 
auto-tuning. 
 
8 PG1 
Position 
loop 
gain 1 
Set the position loop gain for the model loop. 
Determine the tracking ability regarding the 
position commands. 
4 to 1000 (1/s)  70 
 
  
(Not 
used.) 
 
10 EMGt  Deceleration 
control time 
constant 
Set the deceleration time from the clamp speed 
(Aspeed1). For normal rapid traverse, set the 
same value as the acceleration/deceleration time 
constant.  
0 to 32768 (ms)  500 
11 
 
  
(Not 
used.) 
 
12 
 
  
(Not 
used.) 
 
13 MBR 
Vertical 
axis 
drop 
prevention 
time 
Input the time the servo OFF is delayed during 
servo OFF command. Increase the setting by 
100ms at a time and set the minimum value where 
the axis does not drop. 
0 to 1000 (ms)  100 
14 NCH 
Notch 
filter 
No. 
Set the frequency of the machine resonance suppression filter. 
Do not set values without a description. 
Setting 
value 
0 1 2 3 4 5 6 7 
Frequency 
(Hz) 
No 
start
1125
563
375
282 225 188 161