3 - 42 
MELSEC-A
3   SPECIFICATIONS AND FUNCTIONS 
 
3.7.4 Input/output interface internal circuit 
The outline diagram of the internal circuit for the D75P2 external device connection 
interface is shown below. 
:   Wiring is necessary in positioning.   
:   Perform wiring when necessary. 
 
Input/out
-put 
class 
External wiring 
Pin 
No. 
Internal circuit 
Signal name 
Details 
ON/OFF status 
Need for 
wiring 
External 
wiring 
D75P2
Input 
 
11 
 
Near-point 
dog signal 
DOG 
• Near-point dog detection signal for a 
machine zero point return 
  OFF 
 
  ON 
12 
Upper limit 
signal 
FLS 
• Signal for the limit switch provided at 
the upper limit of the stroke. 
• Also used for the zero point return retry 
function. 
  ON 
 
 
OFF 
(STOP)
13 
Lower limit 
signal 
RLS 
• Signal for the limit switch provided at 
the lower limit of the stroke. 
• Also used for the zero point return retry 
function. 
 ON 
 
 
OFF 
(STOP)
14 Stop 
signal 
STOP 
• Signal that stops positioning externally 
• When stopping positioning, this signal 
turns ON in 4ms or more. 
• After this signal has been turned ON, 
positioning is not restarted if this signal 
is turned from ON to OFF. 
 OFF 
 
 
ON 
(STOP)
15 
Speed/ 
position 
changeover 
signal 
CHG 
• Signal that changes from speed control 
to position control in speed/position 
changeover control. 
 OFF 
 
 ON 
16 
External 
start signal 
STRT 
• Signal that performs an external 
positioning start/speed change/skip 
request. 
• To make an external start valid, keep 
this signal ON more than 4ms. 
• Set which function will be used in the 
detailed parameter. 
 OFF 
 
 ON 
35 
Common 
COM 
• Input voltage 24VDC. 
 
 
36 
(+) 
Manual 
pulse 
generator A 
phase 
PULSER 
A+ 
• Terminal to connect a manual pulse 
generator. 
• Introduced product: MR-HDP01 
(Mitsubishi Electric make) 
 
 
(–) 
27 
PULSER 
A– 
(+) 
10 
Manual 
pulse 
generator B 
phase 
PULSER 
B+ 
(–) 
28 
PULSER 
B– 
Input 
Drive unit 
READY 
READY 
Signal for judging whether the drive unit 
is normal or abnormal. 
ON  : Drive unit normal. Positioning 
control enabled. 
OFF : Drive unit abnormal. Positioning 
control disabled. 
 OFF 
 
 ON 
In-position 
signal 
INPS 
• Enter the in-position signal from the 
drive unit. 
• The ON/OFF status can be monitored 
with the remote input (RX). 
 OFF 
 
 ON 
26 
Common 
COM 
• Input voltage 24VDC. 
 
 
Zero point 
signal 
PG0 
• Zero point signal for a machine zero 
point return. 
• Generally, the zero point signal of a 
pulse encoder, etc. is used. 
 
 
24 
25 
Common PG0 
COM
Input voltage 24V/15V/5VDC 
Pin No. 6-25 24V/15VDC 
Pin No. 24-25 5VDC 
 
* The terminal connected to the common line may be either positive or negative.