5 - 10 
MELSEC-A
5   DATA USED FOR POSITIONING CONTROL 
 
5.1.6 Setting items for condition data 
When carrying out "advanced positioning control" or using the JUMP command in the 
"main positioning control", the "condition data" must be set as required. The setting 
items for the "condition data" are shown below. 
Up to 10 "condition data" items can be set for each axis. 
Refer to "Chapter 10 ADVANCED POSITIONING CONTROL" for details on the 
"advanced positioning control", and to section "5.5 List of condition data" for details on 
each setting item. 
 
Control 
 
 
 
 
Condition data 
Main positioning 
control 
Advanced positioning control 
Other 
than 
JUMP 
com-
mand 
JUMP 
com-
mand 
Block 
start 
(Normal 
start ) 
Condition 
start 
Wait start
Simul-
taneous 
start 
Stop 
Repeat-
ed start 
(FOR 
loop) 
Repeat-
ed start
(FOR 
condi-
tion) 
Da.14
  Condition target 
– 
 
– 
 
 
 
– –   
Da.15
  Condition operator 
– 
 
– 
 
 
 
– –   
Da.16
  Address – 
 
– 
 
 
– – –   
Da.17
  Parameter 1 
– 
 
– 
 
 
 
– –   
Da.18
  Parameter 2 
– 
 
– 
 
 
 
– –   
 
 
 :  Set as required ("–" when not set) 
 
 :  Setting limited 
 
–  :  Setting not required (This is an irrelevant item, so the setting value will be ignored. If the value is the default value or within the 
setting range, there is no problem.) 
 
 
 Checking the condition data 
 
Da.14  to  Da.18  are checked with the following timing. 
 
(1)  When the "Start block data" starts 
(2)  When "JUMP command" starts 
(3)  When the test mode using the AD75 software package