6 - 46 
MELSEC-A
6   SEQUENCE PROGRAM USED FOR POSITIONING CONTROL 
 
6.5.3 When using dedicated commands with QCPU (Q mode)/QnACPU 
An example of the program for using the dedicated commands with the QCPU (Q 
mode)/QnACPU is shown below. 
The QnACPU that can use the dedicated commands is only the QnACPU of function 
version "B" or later. 
This program assumes that the CC-Link parameters have been set as indicated below. 
 
Parameter setting item 
Setting value 
Number of modules 
Module head I/O No. 
Module type 
Master station 
Total number of connected modules 
Batch refresh device 
Remote input (RX) 
X100 
Remote output (RY) 
Y100 
Remote register (RWr) 
D200 
Remote register (RWw) 
D100 
Station information 
Station type 
Intelligent device station 
Number of occupied stations 
4 stations occupied 
Transmission buffer size 
64 
Reception buffer size 
64 
Automatic update buffer size 
 
<Parameter setting screen on GX Developer> 
 
When PLC series is QCPU (Q mode) 
When PLC series is QnACPU 
 
<Station information setting screen on GX Developer> 
 
When PLC series is QCPU (Q mode) 
 
 
 
When PLC series is QnACPU