Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
6 - 64 
MELSEC-A
6   SEQUENCE PROGRAM USED FOR POSITIONING CONTROL 
 
6.6.5 Stop program 
The axis stop signal [RY(n+1)3, RY(n+1)4] or a stop signal from an external source is 
used to stop the control. Create a program to turn the axis stop signal [RY(n+1)3, 
RY(n+1)4] ON as the stop program. 
 
The process for stopping control is explained below. 
Each control is stopped in the following cases. 
 
(a)  When each control is completed normally. 
(b)  When the drive unit READY signal is turned OFF. 
(c)  When the CC-Link data link stops. 
(d)  When Initial data setting request (RY(n+7)9) turns ON and Remote station READY 
(RX(n+7)B) turns OFF. 
(e)  When an error occurs D75P2. 
(f)  When control is intentionally stopped (Stop signal from master module turned ON, 
stop from peripheral device, etc.) 
 
The stop process for the above cases is shown below. (Excluding (a) when the 
operation stops normally.) 
 
(1)   Stop process 
 
Stop cause 
Stop 
axis 
Axis 
operation 
status 
(RWrn+7, 
RWrn+15) 
after 
stopping 
Stop process 
Zero point return 
control 
Main 
positioning 
control 
Advanced 
positioning 
control 
Manual control 
Machine 
zero point 
return 
control 
High-
speed 
zero 
point 
return 
control
JOG 
opera-
tion 
Manual 
pulse 
generator 
operation 
Forced stop 
Drive 
unit
 READY 
signal OFF 
Each 
axis 
During 
error 
 Immediate 
stop 
Immediate 
stop 
Fatal stop 
(Stop group 1) 
Hardware stroke 
limit upper/lower 
limit error 
occurrence 
Each 
axis 
During 
error 
 
Deceleration stop/sudden stop 
 
 (Select with 
Pr.38
 ) 
Deceleration 
stop 
Emergency 
stop  
(Stop group 2) 
Remote station 
READY signal 
OFF 
All 
axes 
During 
error 
 
Deceleration stop/sudden stop 
 
 (Select with 
Pr.39
 ) 
Deceleration 
stop 
"Stop" input from 
external device 
Relatively safe 
stop  
(Stop group 3) 
Axis error 
detection (Error 
other than stop 
group 1 or 2) 
Each 
axis 
During 
error 
 
Deceleration stop/sudden stop 
 
 (Select with 
Pr.40
 ) 
Deceleration
stop 
Error in test mode 
Intentional 
stop (Stop 
group 3) 
"Stop signal" ON 
from external 
source 
Each 
axis 
When 
stopped 
(While 
waiting) 
"Axis stop signal" 
ON from PLC 
CPU