9 - 4 
MELSEC-A
9   MAIN POSITIONING CONTROL 
 
9.1.2 Operation patterns of main positioning controls 
In "main positioning control" (advanced positioning control), "
Da.1  Operation 
pattern" can be set to designate whether to continue executing positioning data after 
the started positioning data. The "operation pattern" includes the following 3 types. 
 
Positioning complete
(1) Independent positioning control 
     (operation pattern: 00)
·
Positioning continue
(2) Continuous positioning control 
     (operation pattern: 01)
(3) Continuous path control 
     (operation pattern: 11)
·
 
 
The following shows examples of operation patterns when "1-axis linear control (ABS 
linear 1)" is set in positioning data No. 1 to No. 6 of axis 1. Details of each operation 
pattern are shown on the following pages.  
 
 
< Operation example when "1-axis linear positioning" is set in the positioning data of axis 1 >  
 
(Direction in which axis 1 addresses increase) 
1-axis linear control 
(One motor is driven, and positioning is carried out to an addresses designated in one direction.)
  
Speed 
Positioning data No.1
0
Operation pattern = 11: Continuous path control 
Positioning to address [A] at command speed [a]
No.2
No.3
No.4
No.5
Address
a
b
NO.1
No.2
No.3
No.4
No.5
Speed is changed
without stopping
The machine stops, and 
then continues the next
positioning operation. 
Positioning is terminated
No.6
Control stop
No.1 Start
11
11
01
01
00
Time
Da. 1 Operation pattern
(Positioning data)
(Setting details) 
Positioning to address [C] at command speed [a]
Positioning to address [D] at command speed [b]
Positioning to address [E] at command speed [a]
Positioning to address [F] at command speed [a]
Positioning to address [B] at command speed [b]
Operation pattern = 11: Continuous path control 
Operation pattern = 01: 
Continuous positioning control 
Operation pattern = 00: Independent positioning control
                                      (Positioning complete) 
Operation pattern = 11: Continuous path control 
Operation pattern = 01: 
Continuous positioning control
 
A
E
D
C
B
F
For
 
POINT 
 
When position control of movement amount 0 is executed, the BUSY signal [RXn4,  
RXn5] also turns ON. However, since the ON time is short, the ON status may not  
be detected in the sequence program.