Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
9 - 19 
MELSEC-A
9   MAIN POSITIONING CONTROL 
 
9.1.6 Interpolation control 
  Meaning of interpolation control 
 
In "2-axis linear interpolation control", "2-axis fixed-dimension feed control", and 
"2-axis circular interpolation control", control is carried out so that linear and arc 
paths are drawn using a motor set in two axis directions. This kind of control is 
called "interpolation control". 
In interpolation control, the axis in which the control method is set is defined as the 
"reference axis", and the other axis is defined as the "interpolation axis".   
The D75P2 controls the "reference axis" following the positioning data set in the 
"reference axis", and controls the "interpolation axis" corresponding to the 
reference axis control so that a linear or arc path is drawn. 
The following table shows the reference axis and interpolation axis combinations.   
 
The reference axis and interpolation axis are as indicated below. 
 
Reference axis 
Axis 1 
Interpolation axis 
Axis 2 
 
  Setting the positioning data during interpolation control 
 
When carrying out interpolation control, the same positioning data Nos. are set for 
the "reference axis" and the "interpolation axis".   
The following table shows the "positioning data" setting items for the reference 
axis and interpolation axis.   
 
 Axis 
 
 Setting 
item 
Reference axis setting item 
(Axis 1) 
Interpolation axis setting item 
(Axis 2) 
Same positio
ning data N
os
 
Da.1  Operation pattern 
– 
Da.2  Control method 
Linear 2, Fixed-dimension feed 2, 
Circular interpolation, Circular 
right, Circular left 
– 
Da.3  Acceleration time No. 
– 
Da.4  Deceleration time No.
– 
Da.5  
Positioning address/ 
movement amount 
 
 
Da.6  Arc address 
 
(Only during circular interpolation, 
right arc, and left arc) 
 
(Only during circular interpolation, 
right arc, and left arc) 
Da.7
 Command speed 
– 
Da.8
 Dwell time 
– 
Da.9
 M code 
– 
 
  :  Setting always required 
  :  Set according to requirements (Set to "–" when not used.) 
  :  Setting restrictions exist 
–  :  Setting not required (Unrelated setting item, so any setting value will be ignored. Use the initial 
value or a value within the setting range.) 
*  :  Refer to section "5.3 List of positioning data" for information on the setting details.