Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
9 - 18 
MELSEC-A
9   MAIN POSITIONING CONTROL 
 
2)      When the software stroke limit is valid 
The positioning is carried out in a clockwise/counterclockwise direction 
depending on the software stroke limit range setting method.   
Because of this, positioning with "shortcut control" may not be 
possible.  
 
Example
345.00000°
315.00000°
Positioning carried out in the clockwise direction.
When the current value is moved from 0° to 315°, positioning is carried out in the clockwise direction 
if the software stroke limit lower limit value is 0° and the upper limit value is 345°.
 
 
POINT 
 
Positioning addresses are within a range of 0° to 359.99999°. 
Use the increment system to carry out positioning of one rotation or more. 
 
(b)   Increment system 
Positioning is carried out for a designated movement amount in a 
designated movement direction when in the increment system of 
positioning. 
The movement direction is determined by the sign (+, –) of the movement 
amount.  
    For a positive (+) movement direction .... Clockwise 
    For a negative (–) movement direction ... Counterclockwise 
 
POINT 
 
Positioning of 360°  or more can be carried out with the increment system. 
At this time, set as shown below to invalidate the software stroke limit. 
      [Software stroke limit upper limit value = Software stroke limit lower limit value] 
(Set a value within the range of 0° to 359.99999°.)