Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
9 - 24 
MELSEC-A
9   MAIN POSITIONING CONTROL 
 
(2)   1-axis linear control (INC linear 1) 
 
 Operation chart  
 
In increment system 1-axis linear control, addresses established by a machine 
zero point return are used. Positioning is carried out from the current stop position 
(start point address) to a position at the end of the movement amount set in 
" Da.5
 Positioning address/movement amount". The movement direction is 
determined by the sign of the movement amount.  
 
 
 
-3000 -2000
5000
Positioning control in the reverse direction (movement amount -7000)
Address after positioning control
Start point address
(current stop position)
-1000
0
1000 2000 3000 4000
6000
Example
When the start point address is 5000, and the movement amount is -7000, positioning is carried out to
the -2000 position. 
 
 
 Positioning data setting example 
 
The following table shows setting examples when "1-axis linear control (INC linear 
1)" is set in positioning data No. 1 of axis 1.  
 
Setting item 
Setting example
Setting details 
Axis 1   Positio
ning data N
o. 1
 
Da.1
 Operation pattern 
Positioning 
complete 
Set "Positioning complete" assuming the next positioning data will not 
be executed. 
Da.2
 Control method 
INC linear 1  Set increment system 1-axis linear control. 
Da.3
 
Acceleration time 
No. 
Designate the value set in "
Pr.26  Acceleration time 1" as the 
acceleration time at start. 
Da.4
 
Deceleration time 
No. 
Designate the value set in " Pr.9  Deceleration time 0" as the 
deceleration time at deceleration. 
Da.5
 
Positioning address/ 
movement amount 
–7000.0
Set the movement amount. (Assuming "mm" is set in " Pr.1  Unit 
setting".) 
Da.6
 Arc address 
– 
Setting not required (setting value will be ignored). 
Da.7
 Command speed 
6000.00mm/min Set the speed during movement. 
Da.8
 Dwell time 
500ms 
Set the time the machine dwells after the positioning stop (pulse output 
stop) to the output of the positioning complete signal. 
Da.9
 M code 
10 
Set this when other auxiliary operation commands are issued in 
combination with the No. 1 positioning data. 
 
   * Refer to section "5.3 List of positioning data" for information on the setting details.