Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
9 - 48 
MELSEC-A
9   MAIN POSITIONING CONTROL 
 
9.2.9 Speed/position changeover control 
In "speed/position changeover control" ("  Da.2  Control method" = Forward run: 
speed/position, Reverse run: speed/position), the pulse of the speed set to "
Da.7  
Command speed" is kept output until the stop command is input in the axis direction 
set to the positioning data, and speed control is switched to position control when the 
"speed/position changeover signal" is input. 
The two types of speed/position changeover control are "Forward run: speed/position" 
in which the control starts in the forward run direction, and "Reverse run: 
speed/position" in which control starts in the reverse run direction.  
Speed/position changeover control is available in two types: "increment method" and 
"absolute method". 
 
(1)   Increment method (INC mode) 
After control is switched to position control, positioning is carried out by the 
movement amount set in " Da.5  Positioning address/movement amount". 
 
(2)   Absolute method (ABS mode) 
After control is switched to position control, positioning is carried out to the 
address set in " Da.5  Positioning address/movement amount". The ABS mode 
is valid only when " Pr.1  Unit setting" is "2: degree". 
 
 
Pr.1  Unit setting 
Cd.36 
Speed/position  
changeover control  
(ABS mode) function valid flag 
mm inch 
degree 
pulse 
INC mode (bit 0: 0) 
 
 
 
 
ABS mode (bit 0: 1) 
 
 
 
 
: Can be set,  : Cannot be set. 
 
Select the INC mode or ABS mode using " Cd.36  Speed/position changeover control 
(ABS mode) function valid flag".
 
Setting item 
Setting 
value 
Setting details 
Buffer memory 
address 
Axis 1 
Axis 2 
Cd.36  Speed/position changeover control 
(ABS mode) function valid flag 
0 INC 
mode 
1189 1239 
1 ABS 
mode 
* For more information on the setting details, refer to section "5.7 List of control data". 
 
 Changing over from speed control to position control  
(Common to INC 
mode
 and ABS mode) 
 
(1)  The control is changed over from speed control to position control by the 
external signal "speed/position changeover signal".  
(2)  Besides setting the positioning data, the "Speed/position changeover enable 
flag (RY(n+2)8, RY(n+4)8)" must also be turned ON to change over from 
speed control to position control. (If the "Speed/position changeover enable 
flag (RY(n+2)8, RY(n+4)8)" turns ON after the speed/position changeover 
signal turns ON, the control will continue as speed control without changing 
over to position control. Only position control will be carried out when the 
"Speed/position changeover enable flag (RY(n+2)8, RY(n+4)8)" and 
speed/position changeover signal are ON at the operation start.) 
 
 Operation chart (Common to INC mode and ABS mode) 
 
The following chart (Fig.9.10) shows the operation timing for speed/position 
changeover control. The "in speed control flag" (RX(n+1)C, RX(n+4)C)" is turned 
ON during speed control of speed/position changeover control.