9 - 49 
MELSEC-A
9   MAIN POSITIONING CONTROL 
 
t
V
Positioning start signal
OFF
ON
BUSY signal
OFF
ON
Positioning complete signal
OFF
ON
Speed/position changeover signal
ON
Speed control  Position control
Dwell time
In speed control flag
Speed/position
changeover enable flag
Da. 7 Command speed
Movement amount set in" Da. 5
Positioning address/movement 
amount" (In INC mode)
OFF
OFF
OFF
ON
ON
[RY(n+1)0, RY(n+1)1]
[RXn4, RXn5]
[RXn7, RXn8]
[RY(n+2)8, RY(n+4)8]
[RX(n+1)C, RX(n+4)C]
Address set in " Da. 5  Positioning
address/movement amount"
(In ABS mode)
Fig. 9.10 Speed/position changeover control operation timing 
 
 Operation example 
 
The following operation assumes that "
Pr.1  Unit setting" is "2: degree", " Pr.22  
Current feed value during speed control" setting is "1: Update current feed value", 
and the speed/position changeover signal is input in the position of 90.00000 
[degree] current feed value during execution of "forward run:  
speed/position" set in "  Da.2 Control method". 
(The " Da.5  Positioning address/movement amount" setting value is 
270.00000[degree].) 
0.00000
90.00000
270.00000
0.00000
90.00000
Stop at 270.00000
[degree]
[ABS mode]
0.00000
90.00000
90.00000+270.00000
=360.00000
=stop at 0.00000[degree]
[INC mode]
Speed/position
changeover signal ON