Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
10 - 16 
MELSEC-A
10   ADVANCED POSITIONING CONTROL 
 
10.3.9 Restrictions when using the NEXT start 
The "NEXT start" is a command indicating the end of the repetitions when executing 
section "10.3.7 Repeated start (FOR loop)" and section "10.3.8 Repeated start (FOR 
condition)".  
 
The following shows the restrictions when setting "7: NEXT start" in the "start block 
data".  
 
(1)  The processing when "7: NEXT start" is set before execution of "5: FOR loop" or 
"6: FOR condition" is the same as that for a "0: normal start".   
 
(2)  Repeated processing will not be carried out if there is no "7: NEXT start" 
command after the "5: FOR loop" or "6: FOR condition" command. (Note that an 
"error" will not occur.) 
 
(3)  Nesting is not possible between "5: FOR loop" and "7: NEXT start", or between 
"6: FOR condition" and "7: NEXT start". A warning "FOR to NEXT nesting 
structure" (warning code: 506) will occur if nesting is attempted. 
 
[Operating examples without nesting structure]  [Operating examples with nesting structure] 
Start block data 
Da.12  Special start 
command 
 
Start block data 
Da.12  Special 
start command 
 
1st point 
Normal start 
1st point 
Normal start 
 
2nd point 
FOR 
 
2nd point 
FOR 
 
3rd point 
Normal start 
3rd point 
Normal start 
 
4th point 
NEXT 
4th point 
FOR 
 
 
5th point 
Normal start 
5th point 
Normal start 
6th point 
Normal start 
6th point 
Normal start 
7th point 
FOR 
 
7th point 
NEXT 
8th point 
Normal start 
8th point 
Normal start 
9th point 
NEXT 
9th point 
NEXT 
 
 
 
 
 
 
 
 
 
  A warning will occur when starting the 4th 
point "FOR". 
The JUMP destination of the 7th point "NEXT" 
is the 4th point. The 9th point "NEXT" is 