Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
10 - 22 
MELSEC-A
10   ADVANCED POSITIONING CONTROL 
 
  Start time chart   
 
The following chart shows a time chart in which the positioning data 1, 2, 10, 11, 
and 12 of axis 1 are continuously executed as an example.   
 
(a)      Start block data setting example 
 
Axis 1 start 
block data 
Da.10  Shape
Da.11   Start 
data No. 
Da.12  Special 
start command 
Da.13  
Parameter 
1st point 
1: Continue 
0: Normal start 
– 
2nd point 
0: End 
10 
0: Normal start 
– 
 
 
 
 
 
 
 
 
 
 
 
(b)   Positioning data setting example 
 
Axis 1 position-
ing data No. 
Da.1  Operation pattern 
01: Continuous positioning control
2 00: 
Positioning 
complete 
 
 
10 
11: Continuous path control 
11 
11: Continuous path control 
12 00: 
Positioning 
complete 
 
 
 
(c)   Start time chart  
 
[RY(n+1)0]
Remote station READY signal
D75P2 READY signal
[RXn1]
[RXn4] 
Positioning complete signal 
V
t
Error detection signal
Positioning data No. 
12(00)
Operation pattern 
1(11)
1st point [buffer memory address 4300]
2nd point [buffer memory address 4301]
11(11)
10(11)
2(00)
7000
1
-32767
10
(8001
H
)
(000A
H
)
Positioning start No.
Cd.31  Positioning starting point No.
Positioning start signal
[RXn0]
Start complete signal
BUSY signal
[RXnA]
[RXn7]
[RX(n+7)B]
[RWwm]
Dwell time
Dwell time
Fig. 10.3 Start time chart for advanced positioning control (block start)