MELSEC-A
11   MANUAL CONTROL 
 
 Precautions during operation 
 
The following details must be understood before carrying out JOG operation.  
 
(1)  For safety, first set "JOG speed (RWwm+6 to 7, RWwm+14 to 15)" to a 
smaller value and check the movement. Then gradually increase the value.  
(2)  If "JOG speed (RWwm+6 to 7, RWwm+14 to 15)" exceeds the speed set in 
"
Pr.32  JOG speed limit value", the workpiece will move at the " Pr.32  JOG 
speed limit value" and a warning "JOG speed limit value" (warning code: 301) 
will occur in the D75P2.  
(3)  The JOG operation can be continued even if a warning "JOG speed limit 
value" (warning code: 301) has occurred.  
(4)  A JOG start signal OFF   ON immediately after the stop signal ON   OFF 
(within 56.8ms) will be ignored. (The operation will not start.) 
 
 Errors during operation 
 
When the operation is stopped by the stroke limit (limit signal OFF), JOG operation 
can be performed after an error reset in the direction in which the limit signal turns 
ON. (The error will occur again if the JOG start signal in the direction in which the 
limit signal turns OFF is turned ON.) 
 
JOG operation possible
JOG operation not possible   
JOG operation
V
ON
OFF
Upper/lower
limit signal