Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
12 - 18 
MELSEC-A
12   CONTROL AUXILIARY FUNCTIONS 
 
12.3.3 Near pass mode function 
When carrying out continuous path control using interpolation control, either the 
"positioning address pass mode" or the "near pass mode" can be selected by setting 
the "
Pr.44   Near pass mode selection for path control". 
 
The "near pass mode" can be selected as the "near pass mode function" to suppress 
the mechanical vibration occurring during speed changes when carrying out 
continuous path control using interpolation control. (Mechanical vibration may occur in 
continuous path control due to the dropping of the output speed during speed 
changes.) 
 
(A)  Positioning address pass mode (factory-set initial value) 
The control is carried out so the machine passes the position set in " Da.5  
Positioning address/movement amount" of each positioning data unit being 
continuously executed. 
 
(B)  Near pass mode 
The extra movement amount occurring at the end of each positioning data unit 
being continuously executed is carried over to the next positioning data unit. 
By not carrying out alignment, the output speed drops are eliminated, and the 
mechanical vibration occurring during speed changes can be suppressed.   
Because alignment is not carried out, the operation is controlled on a path that 
passes near the position set in " Da.5  Positioning address/movement 
amount".  
 
The details shown below explain about the "near pass mode function".   
  (1) Control details 
    (2) Precautions during control 
    (3) Setting the near pass mode function