12   CONTROL AUXILIARY FUNCTIONS 
 
12.7.3 M code output function 
The "M code output function" is used to command auxiliary work (clamping, drill 
rotation, tool replacement, etc.) related to the positioning data being executed.  
When the M code ON signal [RXnD, RXnE] is turned ON during positioning execution, 
a No. called the M code is stored in "Valid M code (RWrn+4, RWrn+12)".  
These "Valid M code (RWrn+4, RWrn+12)" are read, and used to command auxiliary 
work. M codes can be set for each positioning data. (Set in setting item "
Da.9  M 
code" of the positioning data.) 
The timing for outputting (storing) the M codes can also be set in the "M code output 
function". 
 
The details shown below explain about the "M code output function".  
  (1) M code ON signal output timing 
  (2) M code OFF request 
  (3) Precautions during control 
  (4) Setting the M code output function 
  (5) Reading M codes 
 
 
(1)   M code ON signal output timing 
The timing for outputting (storing) the M codes can be set in the "M code output 
function". (The M code is stored in "Valid M code (RWrn+4, RWrn+12)" when the 
M code ON signal is turned ON.) 
The following shows the two types of timing for outputting M codes: the "WITH" 
mode and the "AFTER" mode.  
 
(a)   WITH mode 
The M code ON signal [RXnD, RXnE] is turned ON at the positioning start, 
and the M code is stored in "Valid M code (RWrn+4, RWrn+12)".  
 
Valid M code
M code OFF request
Positioning start signal
BUSY signal
M code ON signal
Positioning
*
*
01
00
m1
m2
*  m1 and m2 indicate set M codes.
Dwell time
V
t
OFF
OFF
OFF
ON
ON
Da. 1  Operation pattern
[RXn4, RXn5]
[RY(n+1)0, RY(n+1)1]
[RXnD, RXnE]
[RY(n+2)6, RY(n+4)6]
[RWrn+4, RWrn+12]
ON
OFF
ON
 
Fig. 12.37 M code ON/OFF timing (WITH mode)