Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
12 - 74 
MELSEC-A
12   CONTROL AUXILIARY FUNCTIONS 
 
(2)   Setting the stepping motor mode function 
To use the "stepping motor mode function", set the required values in the 
parameters shown in the following table, and write them to the D75P2.  
The set details are validated at the rising edge (OFF   ON) of the remote station 
READY signal [RX(n+7)B]. 
  
Setting item 
Setting 
value 
Setting details 
Factory-set 
initial value 
Pr.10  
Bias speed at 
start 
 
Set the minimum speed during start. 
Pr.11  
Stepping motor 
mode selection 
Set "1: stepping motor mode". 
 
                  * Refer to section "5.2 List of parameters" for setting details. 
 
 
 
REMARK 