Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
12 - 73 
MELSEC-A
12   CONTROL AUXILIARY FUNCTIONS 
 
(e)   Restrictions during continuous path control 
 Continuous path control can only be used in the control of 1 axis at a time. 
  Continuous path control cannot be used in 2-axis interpolation control.  
  Positioning deviation may occur if continuous path control is used in 2-
axis interpolation control.  
 Continuous path control can only be used in control in the same direction.  
  The positioning will deviate if continuous path control is used in control in 
which the direction reverses.  
  Use continuous positioning control when carrying out control in which the 
direction reverses in the stepping motor mode.  
 
(f)   Restrictions on INC commands 
Do not use an INC command to carry out positioning in the reverse 
direction after a JOG operation stop or positioning stop.  
If an INC command is used to carry out positioning in the reverse direction 
after a JOG operation stop or positioning stop, the workpiece will be 
positioned 1 pulse from the destination. 
 
(g)   Restrictions on electronic gears 
Vibration may occur if the "movement amount per pulse" value is small in 
the stepping motor mode.  
The use of a 1/1 ratio "movement amount per pulse" value is 
recommended.  
 
(h)   Standard motor and stepping motor mode changeover control 
is not possible 
The position command range and speed command range differ between 
the stepping motor mode and standard mode.  
Because of this, it is not possible to use the stepping motor mode and 
standard mode by changing over between them.  
Normal control cannot be carried out when using the stepping motor mode 
and standard mode after changing over between them. 
 
(i)   Restrictions on speed 
When the stepping motor mode is used, the operation may be controlled at 
a low speed of 20 pulses/second in respect to the set positioning speed.