Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
13 - 9 
MELSEC-A
13   COMMON FUNCTIONS 
 
(1)  "Module status" display details 
"Module status" displays the operation status of the D75P2. 
 
17-segment LED 
Axis indicator LED 
Details 
RUN 
Operating axis flickers. 
During axis operation 
TEST 
All axes turn on. 
During test mode 
IDL Off 
During 
standby 
ERR 
LED of axis in error flickers. During error occurrence 
 
(2)  Axis status" display details 
"Axis status" displays the operation statuses of the axes. 
The status of one axis is switched to that of the other every 0.5 seconds. 
 
17-segment LED 
Axis indicator LED 
Details 
IDLE 
The lit LED changes every 
0.5 seconds. 
During standby 
STOP During 
stop 
JOG 
During JOG operation 
MANP 
During manual pulse generator operation 
OPR 
During zero point return 
POSI During 
position 
control 
VELO 
During speed control 
V- P 
During speed control of speed/position 
changeover control 
V -P 
During position control of speed/position 
changeover control 
BUSY 
During condition waiting, etc. 
E*** 
At error occurrence 
 
Error number display 
When the axis has an error, the error number that has occurred in that axis 
is displayed 0.5 seconds, and the status of the next axis is then displayed. 
 
  (3) "I/O information n" display details 
"I/O information n" displays the status of each signal. 
The "Axis indicator LED" turns on. 
 
17-segment LED 
Axis indicator LED 
Details 
SVON 
Lit when the displayed 
signal is ON. 
Drive unit READY signal 
Z-ON 
Zero point signal 
ULMT 
Upper limit signal 
LLMT 
Lower limit signal 
V-P Speed/position 
changeover 
signal 
DOG 
Near-point dog signal 
 
  (4) Other display details 
The following error message is displayed in the 17-segment LED independently 
of the mode. 
 
17-segment LED 
Axis indicator LED 
Details 
FALT 
 
This error message is displayed when the flash 
ROM value becomes illegal. 
Execute initialization. 
The cause of the error is a hardware fault if the 
error message is displayed after execution of 
initialization.