Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
3 - 2 
MELSEC-A
3   SPECIFICATIONS AND FUNCTIONS 
 
3.1 General specifications 
The general specifications of the D75P2 are given below. 
 
Item Specifications 
Operating ambient 
temperature 
0 to 55°C*
6
 
Storage ambient temperature 
-20 to 75°C*
6
 
Operating ambient humidity 
10 to 90% RH, non-condensing 
(The waterproof type remote I/O module is compliant with IP67. *
4
 
Storage ambient humidity 
10 to 90% RH, non-condensing 
Vibration resistance 
Compliant 
with JIS B 
3502 and IEC 
61131-2 
 Frequency 
Acceleration 
Amplitude 
Sweep 
count 
Under 
intermittent 
vibration 
5 to 8.4Hz 
– 
3.5mm 
10 times each in 
X, Y, Z directions
8.4 to 150Hz
9.8m/s
2
 
– 
Under 
continuous 
vibration 
5 to 8.4Hz 
– 
1.75mm 
– 
8.4 to 150Hz
4.9m/s
2
 
– 
Shock resistance 
Compliant with JIS B 3502 and IEC 61131-2 
(147 m/s
2
, 3 times each in 3 directions X, Y, Z) 
Operating atmosphere 
No corrosive gases 
Operating altitude*
3
 
0 to 2000m 
Installation location 
Inside a control panel*
5
 
Overvoltage category *
1
 
 or less 
Pollution degree*
2
 
2 or less 
 
*
1  This indicates the section of the power supply to which the equipment is assumed to be 
connected between the public electrical power distribution network and the machinery within 
premises. 
Category II applies to equipment for which electrical power is supplied from fixed facilities. 
The surge voltage withstand level for up to the rated voltage of 300V is 2500V. 
*
2  This index indicates the degree to which conductive material is generated in terms of the 
environment in which the equipment is used. 
Pollution level 2 is when only non-conductive pollution occurs. A temporary conductivity 
caused by condensing must be expected occasionally. 
*
3  Do not use or store the programmable controller under pressure higher than the atmospheric 
pressure of altitude 0m. Doing so may cause malfunction. When using the programmable 
controller under pressure, please consult your local Mitsubishi representative. 
*
4  This applies only when all waterproof connectors are being used or when waterproof caps are 
attached to unused waterproof connectors or pipes. (Only the AJ65SBTW -16  has pipes.) 
*
5  The module can be used in an environment other than inside a control panel if the conditions 
such as the operating ambient temperature and humidity are satisfied. 
*6  For the waterproof type remote I/O module (AJ65SBTW -16   only), the operating ambient 
temperature and storage ambient temperature will be as follows.