Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
Appendix - 28 
MELSEC-A
APPENDICES 
 
ABSOLUTE ENCODER 
This is a detector that enables the angle data 
within 1 motor rotation to be output to an 
external destination. Absolute encoders are 
generally able to output 360°  in 8 to 12 bits.   
Incremental encoders have a disadvantage in 
that the axis position is lost when a power 
failure occurs. However, with absolute 
encoders, the axis position is not lost even 
when a power failure occurs.   
Various codes such as a binary code and BCD 
code can be output.     
Absolute encoders are more expensive, more 
accurate, and larger than incremental 
encoders. Refer to "ENCODER". 
 
2
2
2
2
0
1
3
4
2
4
2
3
2
2
2
1
2
0
Slit disk 
Phototransistor 
Fixed slit
Light-emitting diode
Rotating
axis
Binary code
 
 
ABSOLUTE POSITION DETECTION 
SYSTEM 
When positioning is carried out using this 
system, a zero point return can be carried out 
once when the device is started to allow the 
machine position to be stored in the memory 
and the current position to be held even when 
the power is turned OFF. These will be 
compensated if mechanical deviation occurs, 
so a zero point return is not required after the 
power is turned ON again. A motor with an 
absolute position detector and servo amplifier 
and positioning module compatible with an 
absolute position detection system are 
required to configure this system. 
 
 
ABSOLUTE SYSTEM 
This is one system for expressing a positioning 
address.  
Absolute address system.   
This system uses 0 as a reference, and 
expresses the address as the distance from 0. 
The direction is automatically determined, 
even when it is not designated. The other 
address system is the increment system. 
 
No.1
0
No.2
No.3
 
 
 
ACCELERATION TIME 
The parameter acceleration time refers to the 
time from a stopped state to the time the 
speed limit value is reached, so it becomes 
proportionally shorter as the setting speed 
decreases. The acceleration time is 
determined by factors such as machine inertia, 
motor torque, and load resistance torque.   
 
Speed limit value
Setting speed
Speed 0
Acceleration time
Time
 
 
 
ADDRESS 
1)  This is a numerical value to express the 
positioning position, designated in mm, inch, 
angle, or No. of pulse units. 
2)  The memory address. Many addresses are 
stored in the memory. An address is read or 
written after it is designated.   
 
AFTER mode 
This is the mode that outputs the M code after 
positioning is complete (after stopping). 
Clamping can be commanded, drilling 
dimensions can be selected, etc., with this 
mode.  
 
OFF
ON
No.11
No.10
Positioning
 M code (8)
Clamp command