Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3
Appendix - 26
MELSEC-A
APPENDICES
A1SD75P -S3, AD75P -S3
AJ65BT-D75P2-S3
Name
Buffer memory addresses
Remote input/output,
remote register
Symbol
Axis 1
Axis 2
Axis 1
Axis 2
Md.39
816
b0
916
b0
RX(n+1)2
RX(n+4)2
Drive unit READY
b1
b1
RX(n+1)3
RX(n+4)3
Zero point signal
b2 b2
RX(n+1)4
RX(n+4)4
In-position
signal
b3
b3
RX(n+1)5
RX(n+4)5
Near-point dog signal
b4 b4
RX(n+1)6
RX(n+4)6
Stop
signal
b5 b5
RX(n+1)7
RX(n+4)7
Upper
limit
b6 b6
RX(n+1)8
RX(n+4)8
Lower
limit
b7
b7
RX(n+1)9
RX(n+4)9
External start signal
b8 b8
RX(n+1)A
RX(n+4)A
Speed/position
changeover
signal
b9
b9
RX(n+1)B
RX(n+4)B
Deviation counter clear
Md.40
817
b0
917
b0
RX(n+1)C
RX(n+4)C
Speed controlling flag
b1
b1
RX(n+1)D
RX(n+4)D
Speed/position changeover latch flag
b2
b2
RX(n+1)E
RX(n+4)E
Command in-position signal
b3
b3
RX(n+1)F
RX(n+4)F
Zero point return request flag
b4
b4
RX(n+2)0
RX(n+5)0
Zero point return complete flag
b9 b9
RX(n+2)1
RX(n+5)1
Axis
warning
detection
b10
b10
RX(n+2)2
RX(n+5)2
Speed change 0 flag
b11
b11
RX(n+2)3
RX(n+5)3
Zero point absolute position overflow flag
b12
b12
RX(n+2)4
RX(n+5)4
Zero point absolute position underflow flag
Md.49
830 930
RX(n+1)0
RX(n+4)0
Speed limiting flag
Md.50
831 931
RX(n+1)1
RX(n+4)1
Speed change processing flag
(3) The following buffer memory addresses have been added.
Symbol
Buffer memory addresses
Name
Axis 1
Axis 2
Cd.36
1189 1239
Speed/position changeover control (ABS
mode) function valid flag
mode) function valid flag