INSTALLATION 
HOT WATER DELIVERY 
This water heater can deliver water at temperatures which can cause scalding. 
 
It is necessary and we recommend that a temperature limiting device be fitted 
between a Rheemglas or Optima water heater and the hot water outlets in any 
ablution area such as a bathroom or ensuite, to reduce the risk of scalding. The 
installing plumber may have a legal obligation to ensure the installation of this 
water heater meets the delivery water temperature requirements of 
AS/NZS 3500.4 so that scalding water temperatures are not delivered to a 
bathroom, ensuite or other ablution area. 
 
Where a temperature limiting device is installed adjacent to the water heater, 
the cold water line to the temperature limiting device can be branched off the 
cold water line either before or after the isolation valve, pressure limiting valve 
and non return valve to the water heater. If an expansion control valve is 
required, it must always be installed after the non return valve and be the last 
valve prior to the water heater. 
 
If a pressure limiting valve is installed on the cold water line to the water heater 
and the cold water line to a temperature limiting device branches off before this 
valve or from another cold water line in the premises, then a pressure limiting 
valve of an equal pressure setting may be required prior to the temperature 
limiting device. 
 
 
 
 
Two Temperature Zones Using a Temperature Limiting Device 
 